Recent content by uncfan1573

  1. U

    Power Outage Drains Pool

    You need to add a check valve on the suction side of the infinity edge. Sounds like the water from the pool is going back through the main drains on Infinity.
  2. U

    Removing Return eyeballs on a liner pool

    Don't take the screws off. It should unscrew, may take some extra help from some channel locks
  3. U

    Main Ignition Failure Rheem M406A-EN-C Heater

    Is your gas valve on inside heater? If yes Check the injectors and make sure they are not clogged with cob webs.
  4. U

    Closing pool - how do I winterize the main drain?

    Honestly I don't see to many plumbed in that way in ky. In used to blow through it and have a rubber plug ready and remove the blower at the same time plugging it as fast I could. That worked but I wanted a more secure way of doing it.
  5. U

    Closing pool - how do I winterize the main drain?

    I make a temp valve out of pvc that can screw into the port inside the skimmer. I tried this last year on a customers pool and worked really good. Make sure you thread tape the threaded piece that you screw into skimmer
  6. U

    Liner installed over old jet - what to do?

    No I never take them out. Just get a 2'×2' square and should cover it pretty easy Or if it's just a little pvc sticking out take a sawzall and cut as much off as you can. Or even a angle grinder
  7. U

    Pool leak bucket test results in......Help me interpret

    My new guess would be the light niche or conduit that the wires run through
  8. U

    Pool leak bucket test results in......Help me interpret

    Sounds like we found the culprit!
  9. U

    New Hayward AquaRite Goldline SWG

    How many gallons is the pool? one thing in have found with the Hayward salt system if you get the salt level to high. It will freak the system out and cause it to read low. And you know it's higher then that. If you have a local pool store, you may want to take a sample in and let them test it...
  10. U

    New Hayward AquaRite Goldline SWG

    Check and make sure the "cell type" setting is correct. Press the diagnostic button untill you will see one of the following t-3, t-5, t-9, t-15. Yours should be on t-15
  11. U

    Safety Cover installation instructions for Paver Brick

    Just did this one today! "waste" has you going in the right direction. Just take your time going through the pavers and I like to use a smaller pilot hole also and keep my bits wet to keep the pavers from breaking.
  12. U

    Closing pool - how do I winterize the main drain?

    Which means when blowing out the main drain, after you see the bubbles coming out you turn the valve to turn the main drain off. This airlocks the drain
  13. U

    Closing pool - how do I winterize the main drain?

    So when you go full skimmer that will shut your main drain off.
  14. U

    Anybody ever leave the solar cover on for the winter?

    I'm surprised it would be evaporating through a solid cover. Are you sure you don't have a leak?
  15. U

    Closing pool - how do I winterize the main drain?

    If you can post a pic of the valve.