      swamprat69 replied to the thread Jandy LRZE Ignition Issue.
      In what order did you replace the ignition control and the gas valve?
    • swamprat69
      swamprat69 replied to the thread Jandy LRZE Ignition Issue.
      I think that this may be the manual for your heater...
    • swamprat69
      Just saw the videos. The whole burner flame should look like the flame does at the far end of the burner (defined two tone blue flame)...
    • swamprat69
      The yellow at the pilot is probably due to dirt rerstricting the pilot orifice and a new pilot assembly should correct that. For the...
    • swamprat69
      Flame rollout is indicative of a blockage to the flow of combustion byproducts. What condition were the burners in when you cleaned...
    • swamprat69
      It looks as if you have multiple areas of concern ( bottom right and midlevel front ). Aphoto of the entire front of the exposed heater...
    • swamprat69
      A lot of things seem to be "off" in what you are showing. The 3 pressure switches seem to have different WC setpoints ???? Which one was...
    • swamprat69
      Before opening up the combustion chamber to check for any blockages I would follow the AO troubleshooting guide in the heater manual on...
    • swamprat69
      Sorry to having been silent for a while but my brother has been visiting and "forced ?" me to play poker constantly for more than a...
    • swamprat69
      Not sure about total length of the straight runs from the picture. depending on the length of the straight runs and the flexibility of...
    • swamprat69
      This should be the manual for your heater...
    • swamprat69
      swamprat69 replied to the thread Heaters and flow.
      A higher flow rate would definitely increase the heat transfer coefficient, but the increase would not be proportional. The increase in...
    • swamprat69
      swamprat69 replied to the thread Problem with heater.
      It is entirely possible that the problem is not with the gas valve, so I would first try to get a qualified technician to do a throrough...
    • swamprat69
      swamprat69 replied to the thread Problem with heater.
      Both K and H in the 7th digit designate a slow opening gas valve, You could go with a competitors valve that crosses to your original...
    • swamprat69
      swamprat69 replied to the thread Problem with heater.
      Your heater does not look like it has been cleaned and operation checked by a qualified technician in a while. This can effect its...