Recent content by steggall

  1. S

    Jandy PDA wasn't displaying Aquapure info.

    I had a problem that some people had posted in the past, namely that their Jandy PDA wasn't displaying the Aquapure SWG information or the salt level in their pool. As most people have posted, a power cycle usually fixes the problem, and I discovered that to be true, but one important part was...
  2. S

    Jandy PDA missing Aquapure Data

    I just had the same issue with mine. A complete power cycle did the trick. I had to make sure and power cycle everything (pump, heater, and the panel). Just doing the panel did not fix the issue, but when I also power cycled everything then the Aquapure data returned to my PDA.
  3. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    OK, everybody. I SLAMmed the pool last weekend, and the chlorine levels seem to be maintaining now. Sorry for not replying sooner. I'm away for a good part of the week and I only get to check these things over the weekend. - - - Updated - - - I haven't forgotten about checking the...
  4. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    I checked all the levels, made sure the pH and Alkalinity were good, added liquid chlorine and then left it running overnight. The chlorine level actually went up slightly overnight. I'll take another reading at the end of the day.
  5. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Current pump run is 8 hours per day. When the SWG was working that was the normal run time for this time of year. In the middle of summer, I would run it for 12 hours, but it's cooler outside now. The SWG is set to 65%. Cell on light is good. Sensor shows 3400 ppm on the salt, which again...
  6. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Well guys, I ordered a new Jandy Aquapure PLC 1400 through Amazon and I was able to replace my previous cell, along with the new sensor and the power cable. The error 125 and 194 error messages disappeared from my pool control panel. The panel detects flow, and it says that the cell is coming...
  7. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Yes, the local pool chemical company said it was 3300 and they always showed 200 below what my system reported. My system says 3500.
  8. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Actually, here's a question: Assuming the SWG was the problem, and replacing it fixes things, will the error codes disappear, or do I have to do something on the system to reset the codes? I know in my car, once the service light comes on the only way to make it go off is to bring it to the...
  9. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Thanks everyone, for your info. The salinity was good, so I'm ordering a replacement Jandy PLC 1400 salt cell and kit. I'll be back to check other postings, and maybe give my own input, from time to time.
  10. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Box says 3500, which is slightly above what it usually is, especially since we've had a lot of rain this week. It's usually around 3200. I'm getting a sample tested by my pool products vendor later today. The salt cell serial starts if F13GF followed by 4 digits Plug looks good
  11. S

    Hello from Florida's Space Coast!

    Hi Guys, I'm new on the scene here. Originally from the northeastern USA, but now living in Florida's sunny climate. Anyway, this is my first time having responsibility of a pool, and I've been following here for a few months and decided to join. And I finally had a question to post, which I...
  12. S

    AquaPure 125 194 errors and Pool Contractor said Hayward bought Jandy

    Hi Everyone, I'm new to this site but you all seem very knowledgeable. I have a six year old, 16,000 gallon, gunite pool, in Florida. My six year old, AquaPure PLC1400 SWG is giving the 125 194 error codes and the pool has no chlorine. The SWG is clean inside and I do maintain it regularly, so...