Recent content by Puddleman

  1. P

    Adventures with Skimdoctor 2.0

    I get a natural whirlpool in my skimmer I mean like it is so defined even with the pool over full that you would expect to see the flying dutchman and the black pearl engaging in a battle to the bottom. btw I get air because of this issue and have not found a solution for it. ARI S 050 VAC...
  2. P

    Low suction. No Bernoulli effect from all in one skim a round.

    I must be lucky cause Im fighting the whirlpools sucking air in without a skim around. I cant imagine how much air would be sucked in if I had one of those. even with an over full pool from rain I still get whirlpools in the skimmer. thankfully the automatic air bleeder is working to keep air...
  3. P

    Air leak into strainer basket

    oddly today I ran the pump for 8 hours straight while I was at work. when I got home the pump was still primed. I started it to check the air in the filter, was minimal as in just a couple seconds of purging. I am stumped. have had no real rain to speak of I havent done anything different...
  4. P

    Air leak into strainer basket

    Skimmer dye test is using a syringe to put dye at seams etc. In a calm skimmer if theres a crack the dye will seep out of it. I have been wondering if the pump is too big since changing the filter out to a higher flow unit. Theres 3 jets in the pool for return and they seriously churn the...
  5. P

    Air leak into strainer basket

    No valves. But like i said only 1.25inch return lines with 1.5inch suction. That should create some. Filter is up to about 10psi now with vacuuming etc. Not seeing enough change on the amount of air though. Still have to do skimmer dye test.
  6. P

    Air leak into strainer basket

    I have no weir gate. So nothing is slowing the water at the skimmer. Pool level is high due to rain. Still not losing any water.
  7. P

    Air leak into strainer basket

    ok new info on this issue. after 4 days of pump being off, strainer is full of water did not lose prime. turned it on and filter had zero air in it as when I shut it off last. All air in strainer cleared and it took a good 2 minutes before the small air bubbles started in again. what on earth...
  8. P

    Air leak into strainer basket

    This pic quota stuff stops me from posting pics. Basically i dug down to what should have been the 90 from the skimmer to the pump riser, it was a Tee with a iron plug screwed into a threaded adapter. I filled the jole with water to cover it but that didnt change the air either so i ruled out...
  9. P

    Air leak into strainer basket

    Ok no change at all on amount of air entering strainer basket doing the bucket dumps
  10. P

    Air leak into strainer basket

    Will try this today. Cause um all out of ideas unless its a motor shaft seal leak that wouldnt explain the air at pressure but maybe when the pressure drops from purging. I dont know just brainstorming. I have read where air can get in that way at Inyo Pools
  11. P

    Air leak into strainer basket

    I appreciate all of this help. I talked with a pool tech today and he is just as stumped. As i have said i did not have this issue before changing filters. Yet i have checked everything too many times to count. The Pentair filter is rated at almost 3 times the flow rate of the sta rite s8500m...
  12. P

    Air leak into strainer basket

    Everything is full of water even the strainer stays full of water. Its drawing air from somewhere i cannot figure out. It will fill the filter up with air to the point air starts coming out of the jets. Yet it will still have a full strainer basket. The water level in skimmer is an inch from the...
  13. P

    Air leak into strainer basket

    I took some flashlight pics of the skimmer and the vortexs - - - Updated - - - Notice the thousands of tiny air bubbles on the skimmer basket.
  14. 20180523_210141.jpg

    20180523_210141.jpg

  15. P

    Air leak into strainer basket

    There are no valves at all. No multiport as uts a cartridge filter system with no waste line. Have you priced the cartridges for a sta rite s8m500.... that and they are beyond a nightmare to clean. The Pentair RP 200 is simple to clean and the cartridges are about $70 versus $700+ fit the s8m500...