Recent content by Omnipotent

  1. O

    Leaking Booster Pump

    Thanks for the feed back, problem resolved. Turns out not only was the pressure side leaking out of the booster pump, but the suction side as well, and this is what was leading to air in the system. All is well now, and as always thanks for the support from the site.
  2. O

    Leaking Booster Pump

    Thanks for the feedback...and yes I meant union...essentially if it needed to be done again, I would have to keep cutting pieces and those pieces get smaller and smaller and eventually you run out of pieces to cut :) Now onto the suction side leak...hopefully someone can chime in there...going...
  3. IMG_2386.jpeg

    IMG_2386.jpeg

  4. O

    Leaking Booster Pump

    All, I've had issues all season, probably longer and never really paid attention to it prior because it just wasn't a big enough problem...well now it is. 2 issues, which may or may not be related - a) Booster pump leaking at the outlet end b) air leak somewhere I would assume suction side...
  5. O

    input - CLI finish "crumbling" off, only on tanning ledge

    So as the title says, I opened the pool this year and noticed some of the finish (pebbles) on my feet as I walked in the ledge. As I started brushing the surface of the pool and got over to the ledge, large amounts of "finish" started coming up...so I then vacuumed it all up and now have quite a...
  6. IMG_1422.jpg

    IMG_1422.jpg

  7. O

    Jandy Aqua Pure 1400 error code 172

    All, just to close out this thread in case someone else comes across it. I replaced the salt sensor with the new variation, set the correct firmware and away we went, everything working as advertised. Thanks again to everyone's assistance. JD
  8. O

    Jandy Aqua Pure 1400 error code 172

    OK, so Salt content is where it was prior to the unit failing....3.3 which is the reading I get. So I guess this means the Salt Sensor is bad? As for which Cell I have: My sensor screws in the bottom so I'm guessing I can just replace that. To your point, I think what I'm understanding...
  9. plc1400_aquapurecellbox_1.jpg

    plc1400_aquapurecellbox_1.jpg

  10. O

    Jandy Aqua Pure 1400 error code 172

    SWG Gurus....I've searched and read. First I addressed the cell which had scale build up....cleaned and reset the unit to come up with the same 172 code. Next did the test on the control board both with water flowing and off...not sure if this makes a difference. Results where not consistent...
  11. O

    First time SLAM

    Ok, so SLAM or should I say lack there of is complete. I knew I probably didn't need to slam the pool, as the water was crystal and FC was fine, but when I opened the pool I had half a million dead worms and two frogs...so it grossed me out and decided a slam was warranted. In any event...OCLT...
  12. O

    First time SLAM

    Ahh, yes. I'm at 31...so no worries.
  13. O

    First time SLAM

    SWG pool...recommended is 70.
  14. O

    First time SLAM

    Thanks...will give it another test in an hour and see where we are at. Thanks on the tip of cutting the agent in half :goodjob:
  15. O

    First time SLAM

    OK...next question....proceeded to do the drop test which I've done regularly over the years, so fairly familiar. In any event, things started out great...extremely pink water. After 40 drops the water turned a murky color, almost like dirty water, maybe rusty looking...kept going to 60 drops...