    H250 gas regulator fail?

    I was able to isolate the issue to the gas valve not opening despite receiving the voltage, felt the click of the solenoid or whatever, pressure on the outlet increased by 0.4 INWC with no ignition despite glowing ignitor. Reading 11 INWC on valve inlet.
  2. M

    H250 gas regulator fail?

    Heard loud and clear on leaving the valve alone. Thanks. By 'tore apart' I meant I followed the troubleshooting steps in the manual, to include checking for proper voltages and gas pressure readings, gas nozzle blockages, etc.
  3. M

    H250 gas regulator fail?

    Hi I have a Hayward H250 heater that I installed myself. It was working great for a couple weeks then threw an IF code. Tore it all apart and found that an old copper pigtail on the propane was causing flow issues. Replaced it. Now the solenoid valve in the heater isn't functioning. Getting 11...