Recent content by markasanders

  1. M

    Intelliflo VSF 3 Running at Higher Speed than Program

    Since you wrote last, I got through to Fluidra who did a complete system wipe and reprogram of iAqualink. I'm going to monitor over the weekend...
  2. M

    Intelliflo VSF 3 Running at Higher Speed than Program

    Thank you. Ok, I actually did change that label but have since changed it back. It seems that the change in speed is random. I did run in spa mode at 2750 rpm for a few minutes and changed back to pool, but it did not change speed to 1750rpm?
  3. M

    Intelliflo VSF 3 Running at Higher Speed than Program

    The Pentair Home App connects and only reports pump status. The App reads "Pump controlled by Automation ". Mixed system is not desirable and is only because of previous owner and my pool professional.
  4. M

    Intelliflo VSF 3 Running at Higher Speed than Program

    Thanks for your reply. I have set a schedule in the WEB app to basically run 24/7, but it does shut down and restart once a day. The Intelliflo just appears to be changing speed on its own. Although I have the Pentair Home app, I only use it to monitor the status of the pump. Attached are...
  5. M

    Intelliflo VSF 3 Running at Higher Speed than Program

    Hello, I am running a Pentair Intelliflo VSF 3 with an iAqualink 3 control system through a communication link. The pumps was installed last year and was performing great. It seemed that everything had been working fine until I reinstalled my intellichlor cell this spring (there is no...