  1. Jschway

    SWG incorrectly reading zero

    We've had a lot of rain! I use a Taylor kit.
  2. Jschway

    SWG incorrectly reading zero

    The actual salt reading is 2400
  3. Jschway

    SWG incorrectly reading zero

    Auto 2800 84 26.6 4.68 100p -3200 Off 2900 84 31.6 0.00 100p -0 Back to Auto 3500 84 26 5.85 100p -4100
  4. Jschway

    SWG incorrectly reading zero

    Done! I remember doing this in the past. What is the reason?
  5. Jschway

    SWG incorrectly reading zero

    Here are my new numbers... Do you see anything of note? Off 3000 (after I reconfigured it) 80 32.1 0.00 100p -0 Off to auto 3000 81 26.5 5.32 100p -2400
  6. Jschway

    SWG incorrectly reading zero

    So here's a picture of the guts of my SWG... It does have a thermistor but it looked to be in good shape. When I was digging into it I remembered I had an old salt cell and decided to hook it up... The old one is actually producing chlorine again... I'm not sure how long so the culprit like you...
  7. 1000004431.jpg

    1000004431.jpg

  8. Jschway

    SWG incorrectly reading zero

    Do you know why the salt is reading as zero?
  9. Jschway

    SWG incorrectly reading zero

    salt reading is 3,000 I use the Taylor kit.
  10. Jschway

    SWG incorrectly reading zero

    Move the switch from Auto to off here are my readings: 0 82 31.7 0.00 100p -0 Moving the switch back to Auto: 0 83 31.1 0.08 100p -0 Moving the switch off for one minute and then back to Auto: 0 84 30.8 0.18 99p -0
  11. Jschway

    SWG incorrectly reading zero

    I love that you know more about my pool than I do! I'll check the voltage asap!
  12. Jschway

    SWG incorrectly reading zero

    Sorry, so the salt cell is only a couple of years old. But it was from the guy in Florida who rebuilds them. First one I got I had issues. He sent me the current one I'm using. Here is a picture of the SWG... Ill grab some info off my salt cell asap. (When I get home)
  13. 2024-07-24 08.24.16-min.jpg

    2024-07-24 08.24.16-min.jpg

  14. Jschway

    SWG incorrectly reading zero

    Not sure. I bought the house in 2020 and it was our installed.
  15. Jschway

    SWG incorrectly reading zero

    Tested salt with the Taylor kit reading at 3,000. Here's the readings that my Hayward aqua right is giving me. 0 87 31.3 0.00 100p -0 AL -0 r 1.59 t-15 I read that you can replace the Aqua-Rite Thermistor AS 32 2R025. After watching some videos it looks a little complicated with soldering...