Recent content by johnssc1

  1. J

    Easytouch J20 Port Already Filled For Intelliflo

    It must be the surge card. The cable connects to COM3. COM1 and COM 2 are open
  2. J

    Easytouch J20 Port Already Filled For Intelliflo

    Trying to hook up the low voltage control line for an intelliflo to an easy touch. The J20 port on the board is already filled with a wire that goes back to the other control board. Do I double up the connections? Or do I need to use 'COM1' or 'COM2' on the rear board? They appear to be...
  3. J

    Pentair superflow pump question

    Thanks for the detail. Are there any functional differences between the two? Or is it just for them to keep track of warantee
  4. J

    Pentair superflow pump question

    So 342002 is the new 342001, but I can still buy both, and they are different prices? Is this just an inventory glitch, or are there actual differences between the two?
  5. 1741616101327.png

    1741616101327.png

  6. J

    Superflo 1.5hp 2 Speed Pump Bearing Id

    Model 356630S. Build date 9/17/2016 Checking to see if anyone has done a bearing replacement on this and knows the ID numbers. Its running now, so I am trying to get everything together to do it in one day with minimal downtime, but it seems like there is some variation in bearing IDs on these
  7. J

    Bad bearings?

    This is year 7. Probably worth replacing still?
  8. J

    Bad bearings?

    Pump started up like this. Flow seems normal
  9. J

    Meyco vs Loop Loc anchor spacing

    I'm looking to replace an old Loop loc cover with a Meycolite mesh cover. Those seem to be the only brands with a 14 x 32 option. Is the anchor spacing the same between the two? I would prefer to reuse the old holes at least.
  10. J

    Gelcoat crack in fiberglass above water

    This has been here for at least the 10 years I have owned the pool, so I suspect it was original subsidence. If I poke at it, it seems shallow, so I'm going on the assumption it's gelcoat only Since I'm going to close up soon, I would like to take care of it with some polyester resin. What is...
  11. 20210906_195254.jpg

    20210906_195254.jpg

  12. J

    Clean and clear RP 200 Suction Relief Valve

    I haven't installed it yet. I can't seem to find a good picture of what it's supposed to look like. I'm guessing that there is a particular orifice size it's supposed to have? I bought it online, so I'm really trying to avoid the hassle of sending it back. I suppose I can try and see if the...
  13. J

    Clean and clear RP 200 Suction Relief Valve

    I just bought a new clean and clear rp 200 filter. I was taking it out of the box and noticed a small, fingernail size piece near the suction relief valve. It's not exactly clear how it would fit back on to it, so I'm not sure if this is something sort of injection molding scud or something...
  14. 20210416_075340.jpg

    20210416_075340.jpg

  15. J

    Loose or corroded intellichlor to motherboard connector

    I noticed the intellichlor was out the other day. I unplugged, then plugged it back into the control board, and it worked for another day Now it seens to only work when I hold it in. There is corrosion only on the DC pin. No water seems to be leaking anywhere. If it is just the harness, that...