Recent content by johnnybravojr

  1. johnnybravojr

    SWG Creating bubbles?

    Since we didn't have a working SWG over the weekend, we had to manually chlorinate the water. The chlorine levels are pretty low still so I'm thinking once the SWG gets it back in the normal range it should (hopefully) clear up some.
  2. johnnybravojr

    SWG Creating bubbles?

    I uploaded a video on youtube to make it a little easier to see.
  3. johnnybravojr

    SWG Creating bubbles?

    I just had to replace my IC40 with this Generic Replacement Salt Cell for Pentair IC40 | Discount Salt Pool . Installation was pretty easy. The only strange thing is it seems like when the SWG is running, it produces a cloudy bubble stream. I attached a photo for reference. If I set the SWG to...
  4. 20220628_065454.jpg

    20220628_065454.jpg

  5. johnnybravojr

    Pentair IC40 Cell light flashing green

    One more update; I ordered the generic IC40 from Generic Replacement Salt Cell for Pentair IC40 | Discount Salt Pool . @ImpalaSS and @jeffchap thanks for the recommendation! I'm just hoping it lasts as long (or longer) than the Pentair IC40!
  6. johnnybravojr

    Pentair IC40 Cell light flashing green

    Thank you everyone for all the feedback. Just to update. I cut the green wire, and now the cell light still flashes green and I get a green flash on the high salt indicator. I'm assuming this confirms the cell is bad. I will check out the generic option as well as another IC40 (man they got...
  7. johnnybravojr

    Pentair IC40 Cell light flashing green

    Thank you for your response! I will try that and get back to you. Just to understand, if I cut the wire and the cell light stays green, then I can replace the flow sensor (which has the thermistor built-in)? Does doing this bypass if the phosphate level is high?
  8. johnnybravojr

    Pentair IC40 Cell light flashing green

    I know there's a high chance that the cell is dead but it is currently hard/very expensive to find a new one so I wanted to see if there are any troubleshooting options left. A couple of days ago, my saltwater pool became cloudy. The cell light flashes green (but salt and all other indicators...
  9. johnnybravojr

    Mastertemp 200 - Display completely blank and no LEDs

    Hi Everyone. Just wanted to provide an update. I swapped the transformer -- still blew the fuse. Put the original transformer back in and swapped the control board. The heater now powers up with no blown fuse. Was looking at the "damaged" board closer and the only guess I have now is the...
  10. 1632917190723.png

    1632917190723.png

  11. johnnybravojr

    Mastertemp 200 - Display completely blank and no LEDs

    Thanks for your input. I ordered a transformer too. I have a 42007-0107, but I noticed there was a 42007-0107s. Do you know the difference between the two? I was thinking maybe it is a newer revision. Since both the board and transformer have free returns, I figured no harm. The transformer is...
  12. johnnybravojr

    Mastertemp 200 - Display completely blank and no LEDs

    Thanks everyone for your input. I ordered a new board off Amazon. Once swapped, if the fuse blows instantly I'll get a new transformer. Hopefully it is one of the two. I did check the breaker, looks good. Back side of the board looks good, can't find any visual damage.
  13. johnnybravojr

    Mastertemp 200 - Display completely blank and no LEDs

    @ajw22 I was able to take apart the whole heater unit (top, front and back panels). Couldn't find any chewed or damaged wires. Right now I'm leaning to the board potentially being damaged, there are two pads that have some potential damage (circled in the attached photo). Trying to figure out...
  14. 20210919_133240.jpg

    20210919_133240.jpg

  15. system.jpg

    system.jpg