Recent content by joel1618

  1. J

    Pentair Intelliflo 2 VST 2017 model motor making noise

    So for anyone else looking in the future it ended up that the bearings in the motor were toast. The shaft seal had leaked and water got into the pump, corroded the bearings, and that is was caused the noise. Replacing the bearings in the pump fixed the issue.
  2. J

    Pentair Intelliflo 2 VST 2017 model motor making noise

    Thanks mknauss, I do not need it to connect to automation. The pool is old (built in 1992) and only has 1 suction and 2 returns of 1.5 inch in size. No water features or spa to speak of. The intelliflo was way over powered (put in by a 'pro' but recommended because in my area there is a...
  3. J

    Pentair Intelliflo 2 VST 2017 model motor making noise

    So i took it all apart. Impeller was fine, fan was fine, the motor itself was the part making the noise. I went ahead and bought a pentair superflo vs as I needed to get the pool going. I think the intelliflo needs a new motor. The shaft seal looked pretty bad as well. It's my fault as the...
  4. J

    Pentair Intelliflo 2 VST 2017 model motor making noise

    Thank you guys. I'll check the impeller for debri as well as the fan blade on the back. May just need to take it apart and troubleshoot. I think filter pressure is good. I do have a suction side leak that I haven't been able to locate but is something on the list. I've used dye but haven't...
  5. J

    Pentair Intelliflo 2 VST 2017 model motor making noise

    Thanks mknauss, Here's a video of the sound it's making. https://drive.google.com/open?id=13A2WFqBsQViyuhxkvSlTxrcM3xe-wTKa
  6. J

    Pentair Intelliflo 2 VST 2017 model motor making noise

    So like the title says, the motor is making noise. The current Pentair intelliflo 2 vst offering is a 3 year warranty. Pentair is saying that my 2017 model only had a 2 year warranty at the time (i'm at 2 years 9 months). Anyone experience this with them? $1200 pump going out in 2 years is...