Recent content by jasoraso

  1. J

    Tripping GFCI

    In my experience, breakers can wear out - especially if they are tripped repeatedly, and if they run a close to full load - which I imagine a hot tub w/ electrical heater does. If you had a bad heater/spa control that tripped the breaker many times, I would try replacing the breaker.
  2. J

    Treating water for a Redneck hot tub

    I think it sounds great! Get a bottle of dichlor (chlorine w/ CYA) at the pool store) - use that the first day and add enough to "shock" to about 10ppm (probably just a 2-4 teaspoons in a small tub). The next day (or that night after use) add another TEASPOON (edited) or 2 of dichlor; or 1/4 -...
  3. J

    During Refill FLO error and then No Display

    My display went out, and it was just a fuse. My board has about 3 different fuses, including one just for the display. If you have to replace the board and display, my guess is that you can do it yourself, if you are able to use a voltmeter. I would probably replace the board, display, and...
  4. J

    During Refill FLO error and then No Display

    I would double check all the fuses to see about the display not working. Regarding the FLO error - you might check if the pump(s) has a bleeder valve. My WaterWay pump has a little valve I can open that bleeds out the air. I open it, and water/air comes out. I leave it open for about 5-10...