Recent content by Golfingdawg

  1. G

    Pool pump

    So I came home from work two days ago and noticed that the filter button on my pool control panel was on but the pump wasn't running. I turned it off and tried it again and it didn't come on. I felt the pump and it didnt feel hot like it had burned up. The water level in the pool was fine so...
  2. G

    Salt level is reading very low

    Will do. Thanks again for all your help.
  3. G

    Salt level is reading very low

    I got the Heyward turbo cell T-15 that you sent me the link for. That is what matches up with my old cell. Cell temp is 58, water sensor is 59, air sensor is 60. 25.33V 6.85A
  4. G

    Salt level is reading very low

    I reset the system and when it started back up it started out reading 3100 and I thought things were good. Then it jumped to 4000 so I did what you said and had the water checked. I took a sample to the local pool store and they tested everything. It said my salt level was indeed 4000. So I...
  5. G

    Salt level is reading very low

    So I bought the new cell and installed it. The good news is my red light that indicates a low salt level went away. Initially it read there was 3100 salt level but now it’s showing a 4700 salt level. I haven’t take the water to the local pool store to have it checked but there is no way the salt...
  6. G

    Salt level is reading very low

    Thanks again for all your help guys.
  7. G

    Salt level is reading very low

    On discount salt pools they have a hayward version but it’s the one year warranty where as the generic brands have 3 year warranties
  8. G

    Salt level is reading very low

    Any suggestions on what website to buy one through?
  9. G

    Salt level is reading very low

    -26.75V -3.42A 2100 PPM Cell temp sensor is 57 Water sensor is 58 Air sensor is 64
  10. G

    Salt level is reading very low

    Here is a picture of it.
  11. 306B0147-0F5A-4260-A1E9-D7D11E226124.jpeg

    306B0147-0F5A-4260-A1E9-D7D11E226124.jpeg

  12. G

    Salt level is reading very low

    If I get a new cell because our is pretty old, is it best to go with the Heyward version like I have now or one of the generic brands? Is there a specific pool supply place that you get your cells from?
  13. G

    Salt level is reading very low

    Local pool place says it’s a sensor in my cell and the whole cell will have to be replaced. Mine is a T-15 and they look to be around $500-$600. I just recently cleaned the cell so that shouldn’t be an issue.
  14. G

    Salt level is reading very low

    61 degrees and my salt reading is 1900.
  15. G

    Salt level is reading very low

    I have a salt water pool and an automated system that I control from a panel inside my house. This past summer I replaced the computer board on my main control panel outside. Until a few weeks ago everything was running fine. I started getting a check system light that came on and it was reading...