Recent content by golf4dj

  1. G

    Considering Build in North West Atlanta Area - Builder Suggestions

    After spending a number of years in Southern California and having a pool in our backyard for the last 20 years we have realized that we miss the pool. We moved to the Atlanta area about 1 year ago. Anyway, it seems finding a builder in SoCal was quite easy with a fair amount of competition...
  2. G

    Any suggestions on how long we should run our pumps

    I am trying to find the sweet spot with my new vs pump in SoCal. I initially set the pump to run at 1000 rpm for 8hrs and 2400 rpm for 1hr for skimming. Doesn't seem too be enough circulation as I am fighting algae. Cost savings are dramatic though reducing my overall bill by 1/3. Any...
  3. G

    Another Suction Side Leak Post

    Thanks for the input. I will do some more testing over the next couple of days and I will provide feedback. Sent from my LG-P769 using Tapatalk 2
  4. G

    Another Suction Side Leak Post

    Looking for some help. Recently installed new equipment, all new plumbing, and new jandy valves at my equipment pad. For whatever reason, after I installed the intelliflow VS pump I have a suction side leak that I can't seem to locate. I get a lot of bubbles in my basket at all speeds and...
  5. Main Lines.jpg

    Main Lines.jpg

  6. CAM00031.jpg

    CAM00031.jpg

  7. G

    Help - Plumbing Question and Jandy Valve

    I had the same issue and used a couple 45s to give me more room. In the picture you can see where I needed top do this on two runs. [attachment=0:3fht57uf]uploadfromtaptalk1367784371627.jpg[/attachment:3fht57uf][attachment=0:3fht57uf]uploadfromtaptalk1367784371627.jpg[/attachment:3fht57uf]...
  8. uploadfromtaptalk1367784371627.jpg

    uploadfromtaptalk1367784371627.jpg

  9. G

    New Equipment Suggestions

    Ok, i have finished. It took me two full days due to the fact that my plumbing coming out of the concrete slab was way to close together. As a result i had to use a bunch of 45s to give me a little more room. I went ahead and left the two pvc to cpvc welds where i used pvc only solvent in...
  10. uploadfromtaptalk1367177511903.jpg

    uploadfromtaptalk1367177511903.jpg

  11. G

    New Equipment Suggestions

    Making progress. y pipes are wayto close together but i an getting there. Is it ok tho use Christ's red hot blue glue to join the pvc pipe to the jandy valves? Not sure if three jandy valves are just black pvc our something else. Sent from my LG-P769 using Tapatalk 2
  12. G

    New Equipment Suggestions

    OK, received my clean & clear 520 and the pentair vs pump to go with the Hayward h250 heater that i got off craigslist. Took everything out to start the replacement. Rather than break concrete i think i have just enough room to tie into the existing plumbing above the concrete slab. My...
  13. uploadfromtaptalk1366483602445.jpg

    uploadfromtaptalk1366483602445.jpg

  14. G

    New Equipment Suggestions

    [attachment=0:iyb0f3xk]Main Pump(1).jpg[/attachment:iyb0f3xk][attachment=1:iyb0f3xk]Spa Pump1.jpg[/attachment:iyb0f3xk]OK, here i go with a couple more questions. 1. Looks like I am leaning toward the Pentair VS Pump ($200 rebate in SoCal) and will use only for circulation which includes a...