D
Featured content
0
Reaction score
57

Joined
Last seen

Latest activity Postings Media About

    • D
      Darin replied to the thread Aack.. dropped rock in skimer.
      The text above says use a plumbing snake like device that will make the corners. Think about a stiff electric cord, (conductor) without...
    • D
      Darin replied to the thread Aack.. dropped rock in skimer.
      Take the divertor valve lid off. Use a plumbing snake like device and push the rock back to the skimmer , something stiff enough to...
    • D
      Darin reacted to JamesW's post in the thread Why did my filter fittings crack with Like Like.
      These marks indicate a pair of pliers were used, which is too much torque.
    • D
      Darin replied to the thread Why did my filter fittings crack.
      That crack is where the gasket is inside. You over tightened it. Only hand tight. Cheap lesson learned. JamesW is correct.
    • D
      Darin replied to the thread Featured Pump failing?.
      Just use the plumbing size you have and apapt to it if necessary. It does not matter. I am sure there are other options but many...
    • D
      Wild, I run my IntelliFlo 24/7, at 1200 RPM most of the time. This speed allows my SWCG to make all the chlorine my pool needs and...
    • D
      Darin reacted to Newdude's post in the thread Vacuuming sand out of pool with Like Like.
      OK so it the needle goes to zero when the pump is off, the gauge is likely fine. And that needle says 16 and 17. If 16 is clean...
    • D
      Darin replied to the thread Vacuuming sand out of pool.
      If i thought that i had a big sand or dust problem i would just get a sand filter. Free sand!! just not the right size.
    • D
      Darin replied to the thread Cover for pool pump.
      I only put the sky over mine, full midwest sun. My pump and filter are 20 years old. Out in the open away from any structure so it...
    • D
      Darin replied to the thread Pump schedule advice.
      During SLAM i run wide open. The rest of the time i run as slow as possible to keep my skimmers functioning. Since you have a SWG that...
    • D
      PInch back you main drain to increase the flow to the skimmers. Your pollen will not go through your filter it will get captured. Don't...
    • D
      Darin replied to the thread Featured Pump failing?.
      I suspect you have a timer problem as TexasSplash eluded to. In the mean time until you determine that it is not timer, turn on the...
    • D
      Darin replied to the thread Cant find pool leak.
      If you suspect it is on the skimmer(s). Isolate one of the skimmers for a couple of days and monitor Use something like a watertight...
    • D
      Darin replied to the thread Featured Pump failing?.
      Here are a couple of ifs. If your timer is bad fix it you are off to the races. If your motor is bad and you plan on living there for a...
    • D
      Darin replied to the thread 2 valves or 1....
      This is vacuum service not pressure, no worry about collapsing with little pool pump. Usually sch 40 DWV is rated for 10 foot...