Recent content by ewag316

  1. E

    IC40 12A Thermal Circuit Breaker Tripping

    New surge board, 5 minute swap, SGC is working. Not until I pulled the old one out and really inspected it closely did it look like the solder points where the bridge rectifier is attached look (just a little bit) burned. I'm going to replace the bridge rectifier and swap it back out, and if...
  2. E

    IC40 12A Thermal Circuit Breaker Tripping

    Thanks all. Great things to try! Will report back if I figure it out.
  3. E

    IC40 12A Thermal Circuit Breaker Tripping

    Howdy. Tried to research for my exact problem, coming up empty so starting a new thread that will probably sound like many others. I watched this video as well .... Equipment: IC40 connected to EasyTouch including the SCG Power Center History: new IC40 replaced under warranty about 4 months...
  4. E

    IC40 12A Trips when SCG Power Cord is Connected

    I can't get anyone to contact me from customer service. Any suggestions?
  5. E

    IC40 12A Trips when SCG Power Cord is Connected

    Thanks. Seems pretty surprising cell would go bad after only 7 months of use, but who knows.
  6. E

    IC40 12A Trips when SCG Power Cord is Connected

    Howdy. Been reading tons of posts about IC40 problems, here's one more. My 12A SCG breaker is tripped on my EasyTouch. Disconnected SCG power cord from the ET for testing. Transformer is wired correctly (powered through filter pump relay and only energized when pump is called to run) and...
  7. E

    Automated Control of UltraTemp Heat Pump

    Moving the air temp sensor over to solar did the trick. That, and clicking H.PUMP rather than HEATER to activate the thing to "on" ..... Thanks for the help!
  8. Screenshot 2021-12-24 202304.jpg

    Screenshot 2021-12-24 202304.jpg

  9. E

    Automated Control of UltraTemp Heat Pump

    Thanks, probably exactly what I need to know!
  10. E

    Automated Control of UltraTemp Heat Pump

    Awesome... will try the air sensor as a fill in solution
  11. E

    Automated Control of UltraTemp Heat Pump

    Dang.... no.... embarassed I missed that because it sounds like there's my answer. Thank you
  12. E

    Automated Control of UltraTemp Heat Pump

    Owner/builder project. Just got water in and equipment started up two weeks ago. Everything is working fine in manual control, and if I use my iPad everything runs perfectly EXCEPT for starting/stopping the heat pump remotely / automatically from my ScreenLogic system (iPad / iPhone). The...
  13. E

    1st Time Owner/Builder

    Just did startup a week ago.... trying the hot tub for the first time tonight!
  14. 20211215_175324~2.jpg

    20211215_175324~2.jpg

  15. 20211218_073006~2.jpg

    20211218_073006~2.jpg