Recent content by Diver

  1. Diver

    Super CL mode on CircuPool RJ is not designed the best way

    i want the generator to retain the 24 hour run setting in the CMOS memory between power cycles. but since my pump runs 8 hours out 24, it won't be 24 run for me or 14FC for me. if normal run gives me 3 ppm per day, then doubling it would give me a boost of 3ppm per incident.
  2. Diver

    Super CL mode on CircuPool RJ is not designed the best way

    it is dialed in, but my pool is mostly idle with solar cover on. so FC loss is minimal and it sits on rather low setting of the SWG all the time. and when the pool is used, it will burn off an extra 2ppms of FC from the base line. bumping FC to get back to base using SL mode for 24 hours...
  3. Diver

    Super CL mode on CircuPool RJ is not designed the best way

    i can't run on slow speed because i have solar panels.
  4. Diver

    Super CL mode on CircuPool RJ is not designed the best way

    It's supposed to boost the CL generation for 24 hours or until the power is removed. It should've been designed to retain the 24 hour time frame with the power removed. Here is how I saw me using it originally. Let's say at 50% output and no pool use SWG achieves equilibrium and my FC stays...
  5. Diver

    Solar panels can suck air in

    it's the lowest pressure point. the furthest panel from the pump and at the very top. which helps when it comes with plugging the leak.
  6. Diver

    Solar panels can suck air in

    i haven't been participating in this forum for a long time. but i do remember reading mas985 post on hydraulics and the name jumped into my head while writing my post. i think we had a few discussions back in the days. i was thinking it would be impossible to have vacuum at the top of the...
  7. 1716913886347.jpeg

    1716913886347.jpeg

  8. Diver

    floater stuck by the skimmer

    thanks., i guess if it floats away after pump is off then it's ok. pucks in the skimmer are ok when pump is running too, but they for sure won't float away when pump is off.
  9. Diver

    floater stuck by the skimmer

    i can't use my inline chlorinator due to switching to swg and i want to use up some trichlor pucks (yes, i'm aware of CYA) . i got a floater since i don't want to use it in the skimmer, but the Dang floater floats around and ends up by the skimmer anyway. which defeats the whole purpose. is...
  10. Diver

    Solar panels can suck air in

    I don't know if this is a common knowledge or not, but it was news to me that solar panel placed on the pressure side of the pump can suck air in. But they for sure can. My panels have been a bit nosy since I installed them 6 or so years ago - there was some quite gurgling and water rush heard...
  11. flir.png

    flir.png

  12. Diver

    Finishing trichlor tabs while starting with SWCG

    i use (or used to) them at the beginning of the season when i need to ramp up the CYA in conjunction with the bleach. it did take long, but it was ok - i would use less bleach and it would work on my CYA. what's the idea behind saving them for vacation? bc swcg raises the PH and trichlor...
  13. Diver

    Finishing trichlor tabs while starting with SWCG

    Hi! I'm starting this season with an SWCG. I used to have an inline chorinator that I used to bump my CYA, now that spot is taken by the SWCH cell. I have a good amount of pucks left that I want to use up to bring my CYA up. I have an option to drop them into the skimmer, but it seems like SWCG...
  14. Diver

    Circupool RJ 60 oxidation signs on the elements?

    I recently received new RJ60 system and I notice some irregularities on the electrode surface. They are not uniform grey, there are covered in spots that seems like oxidation - browning, greenish spots. I'm attaching a pic, but it's a bit hard to see since the cell itself is quite shiny I...