Recent content by dbg

  1. D

    Repaired '92 heater Jaars EPC due to mouse-bitten Thermistor wires

    Yes, the whole equipment room is a functional museum that I am thinking to renovate. Starting from getting remote control maybe. 15x30x3'3"-7'10" 17k gal. Gunite/plaster pool, 8X8 Spa, Laars EPC II 400 heater, Pentair CCP520 Filter, Pentair WFE4 Filter Pump, Polaris 280 Vac Sweep, Polaris PB4...
  2. D

    Teledyne Laars Series 2 Model: ESC 400N not igniting.

    I have fixed my Teledyne Laars Series 1 EPC II 400 heater, see my recent post. It was due to the thermistor wires got bitten by mouse. Reconnecting the wires fixed my problem. And the trouble shooting steps listed there might be similar to your if you can find the PDF Manuel from the Internet.
  3. D

    Repaired '92 heater Jaars EPC due to mouse-bitten Thermistor wires

    Reconnected thermistor wires on June 12, 2015 - Found my pool heater failed to ignite in May 2015. It was working last winter. This is a Teledyne Jaars Series 1 EPC II 400 unit, see Pic.1. - Opened the front panel and cleaned mouse nest and debris earlier, and spotted two wires hanging...
  4. D

    DIY Pool restoration project

    Nice project! Thanks Sent using Tapatalk