    Pool heater repair

    i know this is old, but was your heater also an IDL H400? i'm curious as i got a replacement oring for mine that is identical to @swamprat69 and i'm fairly certian it is an OEM hayaward ring, but it is round, not oval as you are mentioning. wondering if your model has that shape and OP does...
  2. C

    H400 heater leaking

    Well how bout that. Thanks
  3. C

    H400 heater leaking

    I don't think this thing has any internal or external bypass, but it is only leaking when it it running or trying to fire up. I have been trying to troubleshoot some other issues, but as I'm sitting here recently, I can clearly see that it's got a running drip only when it's is running or trying...
  4. C

    H400 heater 24v gas valve supply

    Well, I wish It wouldn't have gone down this way, but we are temporarily resolved. I am pretty sure that all the limit switches in the water pressure circuit have been working. i did inadvertently set ofoff A0 error when I was playing with the blower pressure switch, I think by having it jumped...
  5. C

    H400 heater 24v gas valve supply

    Couldn't be more obvious now. Thanks for for patience with this..will verify those tomorrow. Greatly appreciate the spoon feeding.
  6. C

    H400 heater 24v gas valve supply

    I was referring to #5 and #6 in the image below. I see from the parts list #6 is it. I did try to look through to find a list of what limits might be needed to check, but haven't found anything yet.
  7. 1719715621280.png

    1719715621280.png

  8. C

    H400 heater 24v gas valve supply

    Yeah, I didn't look for the glow, but even the external part was smoking hot. Are the vac switch(es) one or both of the large diaphragm pots up above the boards?
  9. C

    H400 heater 24v gas valve supply

    Hello, been a couple years recently trouble free but having problems again with my hayward h400 heater. The blower is perpetually cycling with no gas (no valve click and no 24vac signals while my ps8 controller is trying to start it up) my control board is getting 24v, but the orange and white...
  10. 20240629_111800.jpg

    20240629_111800.jpg

  11. 20240629_111226.jpg

    20240629_111226.jpg

  12. C

    Heater cooking my children?

    Thanks, Added some replies above and will try again looking at the actual heater (no kids waiting this time)
  13. C

    Heater cooking my children?

    (No children were actually cooked) I just turned on my hayward heater the first time this year via my ps8 remote to the jacuzzi in my inground. And while the water temp read 78F, the kids waiting to get in came in telling be it was so hot. Ir gun tells me it was 105... anyone have the quick look...
  14. C

    Can there be something bad on the board making cells go bad

    Unfortunately the only warranty place by me will only replace dealer/installer installed cells, making the whole process ridiculous. There used to be a service center in driving distance that would check and replace any cell with a receipt,, but they are no longer around. I feel like it's a...
  15. C

    Can there be something bad on the board making cells go bad

    Ebay so the last two were this listing, granted when I got them they were under 300. I didn't expect hayward quality, but I didn't expect them to die at 9 months. In the summer, they run high, like 75% and winter maybe 25%. My pool runs 8 hours a day on low. The previous cell was a glx hayaward...