Recent content by bremeau

  1. B

    Aqua Ultraviolet

    Then I will probably not replace that lamp, as this forum seems to have no one using an Ultraviolet to sterilize water and no one seem to justify that it would reduce chlorine conception either. I am in charge of the pool maintenance, I no longer use someone for it. As a matter of fact, I just...
  2. B

    Aqua Ultraviolet

    After all my filters have run on Friday night, I just to go to my local Leslie's Pool store on Saturday with a bottle of my pool water that I take from 1 foot under, they do all the analysis and recommend the chemicals and quantities. I buy the acid and chlorine in liquid by the gallon.
  3. B

    Aqua Ultraviolet

    I measure PH & all every weekend and manually add acid, chlorine, and stabilizer as needed.
  4. B

    Aqua Ultraviolet

    Yep, here is my system: 22,000 gallons pool (40' long x 14' wide x 4'-8'deep) with elevated SPA (7' x 7') built in 2010 Control System: Pentair IntelliTouch System i7+3 Filter Pump: Pentair STA-RITE IntelliPro VS-3050 Variable Speed Pump Pool in floor cleaning, pool stream jets, and spa jets...
  5. B

    Aqua Ultraviolet

    I have Aqua Ultraviolet Classic Series General Purpose UV Sterilize https://aquaultraviolet.com/products/uv-sterilizers/classic-series/ I realize this weekend that the lamp had burned out, now these are very expensive: https://aquaultraviolet.com/product/sl-lamps/ - Are they worth it? - Are...
  6. B

    SPA Water not recycle in the Pool?

    My Spillway is all set pumping water from the pool drain into the SPA return which in turns overflows back to the pool. I figured an hour of spillway daily should (before running the SPA itself) should be good enough (after all the SPA is only a 1000 gallons). Now that leads to your point about...
  7. B

    SPA Water not recycle in the Pool?

    All right then I will program it: name one of your unused Feature Circuits "Spillway" and then set it's function to "Spillway" I only have the Pentair IntelliTouch Indoor Wired Control Panel but it should be there in the Setup menu.
  8. B

    SPA Water not recycle in the Pool?

    You are right that it is all about the SPA overflow to the Pool which I assume is what is know as Spillover on the pool controllers. I assume all this was programmed by default in the control system (Pentair IntelliTouch System i7+3) but apparently not. Observing the valve actuators in the pool...
  9. B

    SPA Water not recycle in the Pool?

    Yes I assume the SPA spillover water returns to the pool, but for this to work I assume that in SPA mode (i.e. filter return yo the SPA) it would have to drain from the pool , right? In such case how can you warm up the SAP only?
  10. B

    SPA Water not recycle in the Pool?

    22,000 gallons pool (40' long x 14' wide x 4'-8'deep) with elevated SPA (7' x 7') built in 2010 Control System: Pentair IntelliTouch System i7+3 Filter Pump: Pentair STA-RITE IntelliPro VS-3050 Variable Speed Pump Pool in floor cleaning, pool stream jets, and spa jets pumps: Pentair STA-RITE...
  11. 2019-10-19_15-59-06_IMG4207.JPG

    2019-10-19_15-59-06_IMG4207.JPG

  12. 2019-10-19_15-58-59_IMG4206.JPG

    2019-10-19_15-58-59_IMG4206.JPG

  13. B

    SPA Water not recycle in the Pool?

    I have a pool with an above ground spa. As with most pool plumbing, I have two actuator valves for spa vs pool drain, and spa vs pool return. They are working in sync to be either spa drain and return, or pool drain and return. This makes sense when heating up the SPA, but do they alway work...