Recent content by Bradenwb

  1. Bradenwb

    SWG Pro's/Cons

    Curiously, what RPM do you run your pump at for 24/7?
  2. Bradenwb

    RJ60 Plus installation question - will it fit here? alternatives?

    Good ideas. I will need to double check if there is any issue installing at 45 degrees. That may be the path of least resistance!
  3. Bradenwb

    RJ60 Plus installation question - will it fit here? alternatives?

    I would like to install the cell then flow sensor inline where I have circled in red. Between the elbows is 19.5" of 1.5" pvc. I am reading the manual and it says the flow sensor is 4" and the cell is 15.75" - total of 19.75". Looks like I am just short, .25", to install it. Here's the...
  4. InkedIMG_1495_LI.jpg

    InkedIMG_1495_LI.jpg

  5. Bradenwb

    Heater supply gas pipe confusion

    Looking at the picture above, do you know why I have a regulator right before the pool heater? Wondering why that is there..
  6. Bradenwb

    Heater supply gas pipe confusion

    James, thank you for taking the time to respond. Gas company just confirmed they are delivering 2 PSI to the house and with my meter I can go up to 950 BTU at one time. The only other thing on that line for the pool heater is a fireplace that is not ran during pool season so I should be good...
  7. Bradenwb

    Heater supply gas pipe confusion

    So if I am reading this right, my meter is capable of 425 CFH with 1/2 pipe? So sounds like I have the pressure and meter to use a 400k BTU heater with 5/8? The fireplace is only ran in winter when the pool is closed. Next step would be to get someone to come test pressure to verify before I...
  8. D62E1DD9-E416-43C5-9EE4-C2F482F32403.jpeg

    D62E1DD9-E416-43C5-9EE4-C2F482F32403.jpeg

  9. Bradenwb

    Heater supply gas pipe confusion

    Im using a caliper.
  10. Bradenwb

    Heater supply gas pipe confusion

    I believe there is a regulator, see picture. The line on the left is from the meter which is maybe 25 feet away. It is the 5/8 line. The line on the right goes to the fireplace in the pool house - it is 1/2 diameter. I believe the thing in between is a regulator? How can I tell meter rating? Is...
  11. 584115F1-C1D9-4A0F-BF45-B15AB56FDEA8.jpeg

    584115F1-C1D9-4A0F-BF45-B15AB56FDEA8.jpeg

  12. Bradenwb

    Heater supply gas pipe confusion

    I have a Jandy Laars LX 400k BTU heater that just died. It was installed in 2004. I was looking to replace it with the Raypak 406A equivalent but my pool guy is insisting that I go with the 336k BTU version because the supply gas line is a 5/8" diameter. Reading through the Jandy and Raypak...
  13. Bradenwb

    Did you buy a house that already had a pool?

    We did. I asked for their pool guy's info and for an inspection with him. Met onsite and walked through everything. It was great. He knew everything about the maintenance of the pool since he was the one completing it for years. Also told me all of the stuff coming up.. pool liner and cover...
  14. Bradenwb

    Any recommendations for pool renovators in MN?

    Looking to get quotes to renovate the pool deck, coping, new autocover, liner, and cover box. Doing research now but thought I would see if any of you are in MN and had recommendations based on personal experience?
  15. Bradenwb

    Iron stains AA plus Metal Magic?

    Which tablets exactly? I'll give it a whirl. Thanks Chris for posting this - and everyone that contributed. I am on well water and I have a dual all-house pentek for fill water (5 micron and .5 micron filters). I have slight staining on liner but the white fiberglass stairs are more severe...