Recent content by biostockman

  1. B

    Pentair Mastertemp 200 (R03 Code)

    I couldn't get it to work in any mode prior to replacing the board. I put it into 'Service' mode and the heater kicked on right away which I'm extremely thankful for. Yes, it is currently connected to the IntelliTouch through the Fireman's 2 wire connection.
  2. B

    Pentair Mastertemp 200 (R03 Code)

    So, I got the heater working in Service mode and it's working nicely... Now I need to figure out how to get it working in Auto mode through the ScreenLogic App.
  3. B

    Pentair Mastertemp 200 (R03 Code)

    Ok, So I connected locally and had no response at all. Here is my pic:
  4. thumbnail_Image.jpg

    thumbnail_Image.jpg

  5. B

    Pentair Mastertemp 200 (R03 Code)

    5 buttons, just like the one on the left. I updated my signature also. Thanks!
  6. B

    Pentair Mastertemp 200 (R03 Code)

    Thanks so much for reply! Yes sir, I have it connected through the IntelliTouch system. When I push the heater button on the IntelliTouch panel, it lights up for a second then it goes off. I do not see 888, 128, or 'rX'; I only see r03 for two seconds before it goes dark.
  7. B

    Pentair Mastertemp 200 (R03 Code)

    Hello Everyone - The fun began when I opened the pool a few days ago. The heater was completely unresponsive. I tested and confirmed that the unit is getting power so I assumed that the control board was fried... I replaced the board and membrane pad this morning and when I put power to the...
  8. B

    Screen Logic Connection Issue

    Mine is up and running again
  9. B

    Screen Logic Connection Issue

    Mine has been down since late Saturday, even the Demo doesn't work so I assume that it's on Pentair's end. There are also posts on Twitter regarding the outage.
  10. B

    Pentair Intelliconnect Server Error... Anyone else?

    My connection has been offline since last night, 'Server Error'. Anyone else having an issue or am I riding solo?