Recent content by bennett.tim72

  1. bennett.tim72

    Above ground pool deep end

    I wasn't aware radiant pools did deep ends. Great advice I will google it. I'm just outside of Toronto in Canada!
  2. bennett.tim72

    Has anyone (successfully) made a deep end on an 18x33 oval?

    Following, considering a deep end as well. I was told to stretch the liner I shouldn't go more than 52" deep as the liners are universal.? Not too sure this is the case.
  3. bennett.tim72

    Above ground pool deep end

    Thank you pigeon for the quick reply. I was reading about the ledge and slope. Do you have a buttress free pool? To be dead honest (may sound crazy) I'm not too concerned about the warranty. There are soo many factors to getting any warranty work done anyway. How deep is yours? Is your pool a...
  4. bennett.tim72

    Above ground pool deep end

    Thank you joeself. I believe the buttress free pools have straps from side to side. I also understand a deep end will void manufacture warranty. Is this true. I guess it makes sense.
  5. bennett.tim72

    Above ground pool deep end

    I've decided to upgrade my intex pool with an oval aboveground pool approx 16x24. I read somewhere that you can put a deep end in an above ground pool with an expandable liner. If so how deep can it be? Has anyone done this? Thank you Tim
  6. bennett.tim72

    Rectangular intex pool deep end

    Hi Casey, thanks for your reply. I believe your correct. I was just hoping that someone tried it with success!
  7. bennett.tim72

    Rectangular intex pool deep end

    Hi all, I have an 18 ft x 9 ft x 52" intex ultra frame pool. I was wondering if anyone has attempted to put a deep end in these pools. I have an extra liner ( I bought the exact same pool kit off Kijiji for a dime). Wondering if I could either dig a sloped deep end, say two ft deeper on one...
  8. bennett.tim72

    Mastertemp 400 Heat Exchanger replacement

    My saltwater systems shows I have good flow.
  9. bennett.tim72

    Mastertemp 400 Heat Exchanger replacement

    Hi, I have the same problem with my mastertemp 250. Did you have any issues with taking apart the canister to access the heat exchanger?
  10. bennett.tim72

    Heat exchanger cleaning. Is it a diy?!

    Here is a pic of my thermal regulator
  11. bennett.tim72

    Heat exchanger cleaning. Is it a diy?!

    I wondered if the flex line was the issue as its only 1/2". Yes opening the canister, I do have the red high temp silicone sealant as well. Yes just pressure wash the calcium out. Yes thermal regulator looks ok.
  12. bennett.tim72

    Heat exchanger cleaning. Is it a diy?!

    I can see I would need to replace the gasket and o rings, what else would you think I may need. I've already had the manifold apart with no issues, everything was clean. Tested the sensors and reinstalled. Thank you for your reply!
  13. bennett.tim72

    Heat exchanger cleaning. Is it a diy?!

    Hi all, I wouldn't have a pool without this forum. A big thank you to everyone! <br /> I was wondering if any of you have attempted to take apart and clean their heat exchanger. There is an excellent 2 part 'how too' video on you tube with step by step instructions...
  14. bennett.tim72

    Pentair mastertemp 250 E05 HELP!!!!

    No corrosion at all. The entire heater seems very clean.
  15. bennett.tim72

    Pentair mastertemp 250 E05 HELP!!!!

    I will check now, thank you. The keypad is facing the house to keep kids fingers out of the controls!!!!