Recent content by andrewb_1985

  1. A

    Jandy VersaFlo Bypass, a gimmick?

    Thanks for your input. I am seeing a similar theme on many forums about Jandys sales and warranty practices. I certainly wont be pushing their products. Just out of curiosity, how many hours does it take you to change a heat exchanger on most pool heaters?. Just wondering if its worth...
  2. A

    Jandy VersaFlo Bypass, a gimmick?

    Thanks for the info guys. That is interesting about the warranty. And a good selling point compared to Pentair. I still don't understand the science why limiting the flow saves the heater. I assume there is still stagnant water in the heater with all its chemicals. Even jandy brochure...
  3. Screenshot_20230426_183949_Adobe Acrobat.jpg

    Screenshot_20230426_183949_Adobe Acrobat.jpg

  4. A

    Jandy VersaFlo Bypass, a gimmick?

    Hello folks. I am a licensed gas fitter just getting started installing pool heaters and I have a customer who is dead set on buying a Jandy pool heater because a store salesperson told him about the VersaFlo Bypass. I would rather see him install a Pentair Master temp with cupronickel heat...
  5. A

    No bonding loop from pool

    Yes, I understand that. But would I be correct in saying that to be shocked from 2 objects at a different potential, I would have to come in contact with both at the same time? I can't touch my pool ladder and my pump 40ft away at the same time. The code specifically states to bond all...
  6. A

    No bonding loop from pool

    In my reading the general purpose of bonding comes down to 2 things. Electrical Safety and corrosion. I'm told that especially with an SWG I should have proper bonding and a sacrificial anode to prevent corrosion. The anode would be useless if you didn't bond it to the equipment you were...
  7. A

    No bonding loop from pool

    So I got these screen shots of the Canadian electrical code for pool bonding from my electrician friend. It talks about bonding the pool and everything metallic within 1.5m. Paragraph 1 does say to bond equipment, but specifically mentions lighting equipment. Doesn't say anything about...
  8. IMG-20200418-WA0001.jpg

    IMG-20200418-WA0001.jpg

  9. IMG-20200418-WA0000.jpg

    IMG-20200418-WA0000.jpg

  10. A

    No bonding loop from pool

    I don't have any pool lights. The pool deck is concrete pavers.
  11. A

    No bonding loop from pool

    Hello all. This year I am adding a heat pump to my pool and am basically redoing all the plumbing and electrical for my pool. Currently I have no bonding between any component and I would very much like to get this up to code. I have been reading extensively about pool bonding and think...
  12. A

    Phosphates out of control

    I should also note that there Havnt been any bathers yet and it has rained a fair amount.
  13. A

    Phosphates out of control

    Hello all. I've had my pool open now for 3 weeks. When I first opened it the water had mild cloudiness but started to clear up pretty quick. After a few days I took my first water sample in for testing and the phosphates were at 470. Ph and alc were normal. Salt and stabilizer were low but...