Light blue cloudy water

B_Money1981

New member
May 12, 2025
3
North Wilkesboro, NC
Pool Size
4440
Surface
Vinyl
Chlorine
Salt Water Generator
SWG Type
Intex Krystal Clear
Good evening guys, I'm new to the forum and fairly new to the pool world. 4th year with an 15' Intex above ground pool. Up until this year I've had zero problems with my pool. Upon uncovering pool water was green unlike previous years. I have been trying for a little over a week in getting the water clear but haven't had any luck. I have managed to get the water to a light blue ocean colored type water but it is very cloudy and can not see the bottom. I have shocked it twice now and still not clear and a little lost on what to do now. So here is my test results from a Taylor k-2005 salt test kit:
FC: 1-2ppm
TC: 3-6ppm
CC: 1-2ppm
pH: 7.8
TA: 120ppm
CH: 110ppm
CA: 100ppm
SALT: 3200ppm
BR: 2-4ppm
My pool holds 4440 gallons of water. I run an Intex Sand filter system 1600gph along with an Intex Krystal Clear Saltwater generator (not turned on at the moment). The pool also has the Intex skimmer and a sprayer fountain. I've had some people tell me I needed to raise my chlorine levels up higher to really shock pool until it clears up. So that's why I'm here. Can someone please help me with what I need to do? Thanks guys
 
Follow the
SLAM Process
You will need an fas dpd test kit for that. Your k2005 is missing this.
Or Taylor https://www.google.com/aclk?sa=L&ai...p9qWkZ-NAxW0SzABHd5VAB8Qwg8oAHoECAYQDQ&adurl=
If your cya is reading over 90 then you need to do the diluted test (see step 8)
To confirm your true cya so you can replace the appropriate amount of water as doing the slam process with cya over 70 or so takes alot of chlorine which isn’t cheap. Ideally it would be better at 30-50ppm for slam.
See —> FC/CYA Levels

Until you have that fas dpd kit and can slam properly just add 5ppm worth of liquid chlorine each day to keep things from getting worse.
Use PoolMath to calculate
 
  • Like
Reactions: PoolStored
Good evening guys, I backwashed and rinse the sand filter and then added 1 gallon of liquid chlorine this morning. I retested just now and now my cya level is below what my kit lowest results show. So the cya is 20ppm or below. I have ordered the FAS/DPD kit addition and will arrive tomorrow. My free chlorine level raised to 10-20ppm and my total chlorine was the same at 10-20ppm. All other test results are within the ideal range/goals to reach. I am attaching a picture of the pool water. It is not as cloudy as it was as I can see my brush almost to bottom of pool. Is my levels ready for the slam yet once I receive my FAS/DPD kit tomorrow? Or what should I do now? I really appreciate the help guys
 

Attachments

  • 20250513_172718.jpg
    20250513_172718.jpg
    227.9 KB · Views: 3

Follow the
SLAM Process
You will need an fas dpd test kit for that. Your k2005 is missing this.
Or Taylor https://www.google.com/aclk?sa=L&ai...p9qWkZ-NAxW0SzABHd5VAB8Qwg8oAHoECAYQDQ&adurl=
If your cya is reading over 90 then you need to do the diluted test (see step 8)
To confirm your true cya so you can replace the appropriate amount of water as doing the slam process with cya over 70 or so takes alot of chlorine which isn’t cheap. Ideally it would be better at 30-50ppm for slam.
See —> FC/CYA Levels

Until you have that fas dpd kit and can slam properly just add 5ppm worth of liquid chlorine each day to keep things from getting worse.
Use PoolMath to calculate
Good evening guys, I backwashed and rinse the sand filter and then added 1 gallon of liquid chlorine this morning. I retested just now and now my cya level is below what my kit lowest results show. So the cya is 20ppm or below. I have ordered the FAS/DPD kit addition and will arrive tomorrow. My free chlorine level raised to 10-20ppm and my total chlorine was the same at 10-20ppm. All other test results are within the ideal range/goals to reach. I am attaching a picture of the pool water. It is not as cloudy as it was as I can see my brush almost to bottom of pool. Is my levels ready for the slam yet once I receive my FAS/DPD kit tomorrow? Or what should I do now? I really appreciate the help guys
 

Attachments

  • 20250513_172718.jpg
    20250513_172718.jpg
    227.9 KB · Views: 1