no, I did not.
the fuse is goog.Is the fuse good?
NOTICE: The fuse for the Fireman's Switch is a 1.25 Amp 1-1/4 x 1/4" fast blow fuse.
View attachment 622728
soon as pool pump start, the heater come on, lost tank of propyneDescribe again what your problem is.
Pentair mastertemp 400 is coming on as soon pool pump start. how to find out if is control board or other devices faulty. i stop it running by switch off heater on heater display. i lost whole tank of propane. I though we used it all after we refile the tank, realize heater come up as soon as pool turn, this when i turn of heater. thanks for any help.Describe again what your problem is.
i did that but now display does not come on. i turn heater off from display few days ago now is not coming on.Disconnect the two yellow wire nuts and separate the wires.
Show us a picture of what you did.
Put the wire nuts on the two wire stubs connected to the heater. Do not connect the two wires together.
Does the heater then run?
i did that but now display does not come on. i turn heater off from display few days ago now is not coming on.
no display at all.i did that but now display does not come on. i turn heater off from display few days ago now is not coming on.
When that circuit is closed the heater runs and when it is open the heater will not run. That is the way the EasyTouch controls the heater.no display at all.
What have you done?do not know why display is not working now.
I do not know, trying to figure out what happened.What have you done?
Show us pictures of the wiring you touched.
there is 24 volts to controller bd. still no display or any LED on?I do not know, trying to figure out what happened.