- Oct 24, 2022
- 65
- Pool Size
- 15500
- Surface
- Plaster
- Chlorine
- Salt Water Generator
- SWG Type
- Pentair Intellichlor IC-40
I have an 8 months old Barracuda G3 which has functioned fine until about 2 weeks ago when it stopped operating at startup.
Side wall suction was set at 50% Suction 50% skimmer the variable speed Jandy Pool pump, which was installed 3 months ago, starts at 3000 RPM every morning. There is a Zodiac leaf canister in the line
Until two weeks ago the G3 would start up and run for the 4 hours cleaning cycle. It covered most of the pool bed.
Now, when the pump starts up it just sits there.
I can get it going by 1. Disconnecting and re-connecting the hose 2. Striking or jostling the hose. 3. Setting the wall suction to 80% which then sends it up the side of the pool for the entire cycle rendering it useless.
I disassembled the unit, there are no obstructions and the diaphragm is intact. I believe I have the proper hose length for my pool.
Through trial and error I discovered the unit will not run at less than 2250 RPM.
I’ve used G3s for over 25 years and never encountered issues such as this.
Side wall suction was set at 50% Suction 50% skimmer the variable speed Jandy Pool pump, which was installed 3 months ago, starts at 3000 RPM every morning. There is a Zodiac leaf canister in the line
Until two weeks ago the G3 would start up and run for the 4 hours cleaning cycle. It covered most of the pool bed.
Now, when the pump starts up it just sits there.
I can get it going by 1. Disconnecting and re-connecting the hose 2. Striking or jostling the hose. 3. Setting the wall suction to 80% which then sends it up the side of the pool for the entire cycle rendering it useless.
I disassembled the unit, there are no obstructions and the diaphragm is intact. I believe I have the proper hose length for my pool.
Through trial and error I discovered the unit will not run at less than 2250 RPM.
I’ve used G3s for over 25 years and never encountered issues such as this.