For a reason I can't discern, my IntelliCenter went dark yesterday afternoon and will not power on now. I have been troubleshooting what I can, but have reached the end of what I can figure out, and hoping for some guidance in further troubleshooting the issue.
Best Regards,
Brian
- The breaker for the system board was tripped:
- The high-voltage breaker tests fine.
- The input and outputs of the transformer for the system tested fine.
- Testing the wires coming off the breaker, I get 27.3V on the 24 VAC wires (red) and 20.09V on the 18 VAC wires (orange).
- If I disconnect the system board, I can reset the breaker. If not, it pops again immediately (and I can't reset for +/- 9 seconds).
- I disconnected everything connected to the system board until it wasn't connected to anything but power, and it would still trip the low-voltage breaker.
- There is no visible damage, and the system is less than 2 years old.
- The ONLY thing I noticed at all odd was that one of the wires from my heater to the GHTR harness (which I believe controls calling for heat) had come loose and was not connected).