AQ-TROL-RJ :: Updating cell type on panel to T-15

Quick follow-up. My salt reading leveled off from 3600 down to 3200 and has held there for 30+ minutes. That puts me in the sweet spot for my salt level. Will now monitor the FC for the next 48 hours to see if it holds steady or trends up or down. Not the right forum for that, so I may start a new thread to track/document the chems.
Did you buy the Hayward T-15 or an after market one?
 
As you noted - the T Cell I purchased is from Hayward. Quick update as to the functionality of the modified AQUO-TROL-RJ control panel and new T-Cell-15. Other than a possible loose fit with the Hayward GLX-PCB-DSP Aqua-Rite PCB Display board, the system is working extremely well. I'm in the fine tuning stage where I'm getting my Desired Output % and run time for SWG set. I expect this fine tuning is something that requires constant monitoring as the season/weather changes during the year.
 

JamesW thank you so much for addressing my Hayward GLX-PCB-DSP Aqua-Rite PCB Display readout issue. I was just about to post a quick video showing the on-going issues I'm having with the display readout. I assumed the board needs replaced. Thank you for sharing the repair video from INYO Pools. 👍

 
  • Like
Reactions: JamesW
Thread Status
Hello , This thread has been inactive for over 60 days. New postings here are unlikely to be seen or responded to by other members. For better visibility, consider Starting A New Thread.