E 11 – Motor Control Communication Lost
The motor and the system control unit (DI) are unable to communicate.
When that happens, the pump shuts down.
Remove the User Interface Cover to the voltage compartments.
Refer to Step 1 in Wiring the Motor on page 10.
Verify that the wiring connectors on the circuit board in the Low Voltage Compartment are securely fastened.
Replace the User Interface Cover.
Press any Speed button to restart the motor.
If the fault continues to occur after verifying the wire connections, contact your pool professional or a qualified electrician for service.