I was in my house earlier today and noticed that my pump was off a little earlier than normal. Went out to check on the pool chemistry and the pump was running. Turned off while I was out there. I didn't notice a hum while I was out there like the motor was trying to start. After a minute or 2 it started again, then off again in another minute or 2. Turned it off and got my electrical equipment.
Turned the pump back on and got the following readings.
This motor is just about 2.5 years old. Does this mean that the end of life for this motor is near? Anything else I should check?
Water flow appears to be proper. I clean the filter weekly (typically on the weekends). So I do not expect any obstruction but I am going to clean it now after the Florida daily afternoon rains pass.
I keep this cover on it. Thoughts?
Name plate information.

Meter on one leg.

Turned the pump back on and got the following readings.
- 230V at the motor, which is expected.
- 11.29 amps on one leg.
This motor is just about 2.5 years old. Does this mean that the end of life for this motor is near? Anything else I should check?
Water flow appears to be proper. I clean the filter weekly (typically on the weekends). So I do not expect any obstruction but I am going to clean it now after the Florida daily afternoon rains pass.
I keep this cover on it. Thoughts?

Name plate information.

Meter on one leg.