- Mar 22, 2020
- 54
- Pool Size
- 25000
- Surface
- Plaster
- Chlorine
- Salt Water Generator
- SWG Type
- Hayward Turbo Cell (T-CELL-5)
First season with pool, things have been going pretty smooth so far. About a month ago, I started seeing some green forming in corners and on stairs. I would also finish the evening nice and clean and in the mornings notice patches of what I thought was dirt, kind of yellowish/brown in color, on the floor. I would brush them or put robot in and clean it up, but this has progressively been more and more, no matter how much I clean. I realized, through help on here, that my FC level of 3ppm was low and I should be at minimum of 5 with my CYA level. I upped my SWCG to 13.8 hrs @80% and started raising chlorine. I also added some bleach to raise it more quickly. I have been at 5ppm since this.
I have also been trying to raise the CYA from 60 to 70. Pool Math says around 2 lbs. I put 2lbs in 6 days ago, but forgot to run the pump all night. The next day and again 2 days ago, it was still at 60. I thought maybe I wasted it not running the pump. I only had 1.5 lbs left so I put that in 2 days ago. I ran the pump all night. I'm using dry stabilizer I got off Amazon. https://www.amazon.com/gp/product/B00J7L47HA/ref=ppx_yo_dt_b_asin_title_o01_s00?ie=UTF8&psc=1. I'm putting it in hose and adding to skimmer.
My pump ran all night last night as well, by mistake, so pump has been running for almost 48hrs now. I tested this morning, FC is 9ppm, CYA is still at 60.
#1 How do I stop this build up on the floor?
#2 Why is CYA not going up?


I have also been trying to raise the CYA from 60 to 70. Pool Math says around 2 lbs. I put 2lbs in 6 days ago, but forgot to run the pump all night. The next day and again 2 days ago, it was still at 60. I thought maybe I wasted it not running the pump. I only had 1.5 lbs left so I put that in 2 days ago. I ran the pump all night. I'm using dry stabilizer I got off Amazon. https://www.amazon.com/gp/product/B00J7L47HA/ref=ppx_yo_dt_b_asin_title_o01_s00?ie=UTF8&psc=1. I'm putting it in hose and adding to skimmer.
My pump ran all night last night as well, by mistake, so pump has been running for almost 48hrs now. I tested this morning, FC is 9ppm, CYA is still at 60.
#1 How do I stop this build up on the floor?
#2 Why is CYA not going up?