intellichlor ic40

  1. N

    Corroded power connector on Pentair IC40

    I replaced my Pentair IC40 in April this year and it has just failed with communication error due to water getting into the the connector and corroding the pins. I live in Florida where water and heat is always a problem. I thought the solution was going to be easy. Cut off the old connector and...
  2. C

    Salt cell lights stay on when pump is off

    I have a Pentair Intellichlor IC40 attached to a Pentair Easy touch 8. When then pool pumps go off, or in service mode, the IC40's lights stay on. I recently bought the house with this pool, so I'm trying to tackle the learning curve.
  3. K

    Pentair Intellichlor IC40 Smokes and Fuse Blown

    My Pentair Intellichlor IC40 is pretty old. It's bulging and has some minor cracks and seems completely dead (no lights) I changed the fuse 10 amp, power came back for two seconds and smoke came out of unit. I'm guessing it is completely dead? If so should I be good to just swap it with a new...
  4. Anaheim068

    IC40 connected to easytouch

    Hello, I need some help. I have an IC40 that’s connected to an Pentair Easytouch. My IC40 will only generate chlorine when I run the Super chlorinate feature. Does anyone know why? It calculates the PPM and the flow light turns on but the Cell light only turns on when i run the Super chlorinate...
  5. wcmaness

    Can't Change Chlorine Output

    I have a Pentair system with an IC40 Intellichlor. Recently, my Intellichlor Load Center Surge Board went bad (partially) - so I've ordered a new one (but it's on backorder for an unknown length of time). The Intellichlor itself is still getting power and still works; but since the board...
  6. Steve-D

    New SWG Pool - Rising Chlorine

    We have a new 20,000 gallon SWG Gunite Pool filled on 5/6 and the pump running continuously since then, mostly at low speed (1500-1700 rpm) when not in use or while cleaning. 18 bags (@ 40 lbs each) of salt was added on 5/27 which works out to about 3400 ppm. The Intellichlor IC40 label says the...
  7. M

    Intellichlor Cell Light still Flashing after acid washing

    My Cell light is still flashing green after cleaning it with a 50/50 mixture of muriatic acid and water. When I ha4d press the up button, it goes to 60%. My salt level is slightly high at 3764. Any suggestions?
  8. W

    intellichlor Power center light not powering IC40

    I am attempting to troubleshoot my IC40 as it is not turning on no lights. I noticed in the power center box the led on the board is not lighting up. I am trying to figure out how to use a voltmeter to test voltages in the power center but not finding good places to test with it in the box...
  9. KING-OLE

    Cold Water light on Pentair IC40

    I know there's an older threat, but it suggested I create a new one, so here we go. The COLD WATER light in currently on my Pentair Intellichlor IC40. I live in Houston, TX, so I know the water is not cold in mid April. I tried following the steps in the previous post, pressing the MORE...
  10. E

    Need to Replace Power Supply for Intellichlor IC40 Model 520555

    Hello! I was hoping someone on the forum might be able to help with an equipment question. We currently have our Pentair Intellichlor IC40 Model 520555 plugged into a Pentair Easy Touch Panel, but we think it has a bad board. We would like to replace it with a power supply. Can we replace it...