+ | When you connect the UltraTemp to Pentair automation using the RS-485 data connection you need to add a solar temperature sensor in addition to the air and water temperature sensors.<ref>https://www.troublefreepool.com/threads/intellicenter-quick-reference-information-guide.198056/post-1777329</ref> | ||
+ | |||
+ | When connected using the RS-485 data connection the automation can increase pump speed when the UltraTemp is on. | ||
==UltraTemp and MasterTemp Heaters Together== | ==UltraTemp and MasterTemp Heaters Together== |
Revision as of 21:06, 22 April 2020
Pentair UltaTemp Heat Pump
The Pentair UltraTemp is a Heat Pump with models having 70,000 to 140,000 BTUs of heating capacity. Some models include a chiller capability.
UltraTemp Power Requirements
All models require 230V AC power and except for the 70,000 BTUs, which requires a 40A circuit breaker, other models require a 50A circuit breaker.
Pentair Heat Pump Calculator
Pentair has a Heat Pump Calculator to determine the appropriate size Heat Pump for your location.
Automation Control
The UltraTemp Heat Pump can be controlled by Pentair automation - IntelliCEnter, IntelliTouch, Easy Touch.
When you connect the UltraTemp to Pentair automation using the RS-485 data connection you need to add a solar temperature sensor in addition to the air and water temperature sensors.[1]
When connected using the RS-485 data connection the automation can increase pump speed when the UltraTemp is on.
UltraTemp and MasterTemp Heaters Together
You can have both a Pentair MasterTemp gas heater and a UltraTemp Heat Pump on a pool. They are plumbed in line and hooked up to the IntelliCenter via RS-485 cable. In the programming you have a choice of heaters for your spa and/or pool.
The automation is supposed to regulate temperature via the heat pump 1st - if it can not maintain temp it reverts to the gas heater. But after that it does not go back to the heat pump to maintain. You have to switch it manually.[2]
UltraTemp Chiller Mode
When in chiller mode Pentair forgot to link the temperature differential up to the chiller portion. So if you have a chiller set point of 87 degrees, and your temperature bounces back and forth between 88 and 87 degrees - your fan will cycle on/off, on/off, on/off until the temperature is a constant 87 degrees. That will eventually burn the fan motor up.[3]