− | HUA is Hayward Unique Address that the VS pumps possess. If you have an issue getting OmniLogic to recognize a pump HUA note that the low speed bus numbers are read R to L instead of L to R.You should wire the communication in the following order on the LS Bus, 4,3,2,1. | + | HUA is Hayward Unique Address that the VS pumps possess. If you have an issue getting OmniLogic to recognize a pump HUA note that the low speed bus numbers are read R to L instead of L to R. You should wire the communication in the following order on the LS Bus, 4,3,2,1. |
Revision as of 20:58, 18 September 2019
Hayward OmniLogic
OmniLogic VSP communication issues
HUA is Hayward Unique Address that the VS pumps possess. If you have an issue getting OmniLogic to recognize a pump HUA note that the low speed bus numbers are read R to L instead of L to R. You should wire the communication in the following order on the LS Bus, 4,3,2,1.