− | Stenner Pumps offer a totally enclosed design with a brushed motor for light duty or general intermittent applications. The pumps work well for fluid transfer of Muriatic acid or Liquid | + | [https://stenner.com/ Stenner Pumps] offer a totally enclosed design with a brushed motor for light duty or general intermittent applications. The pumps work well for fluid transfer of [[Acid|Muriatic acid]] or [[Liquid Chlorine]]. The ease of maintenance and replacement parts make it Ideal for a DIY pool owner. |
− | This systems can be used together with automation or independent. There are many models of stenner pumps but the ideal for pool use are Fixed speed with or without timer activation. This way you only have to determine how much run time for the pump to dose. The pump is approved by cULus for indoor and outdoor use and carries NSF 61 and 372. The 25 psi models are tested and certified by Intertek to Standard ANSI/NSF | + | This systems can be used together with automation or independent. There are many models of stenner pumps but the ideal for pool use are Fixed speed with or without timer activation. This way you only have to determine how much run time for the pump to dose. The pump is approved by [https://marks.ul.com/about/ul-listing-and-classification-marks/appearance-and-significance/marks-for-north-america/ cULus] for indoor and outdoor use and carries [https://blog.ansi.org/nsf-ansi-61-2021-drinking-water-system-components/ NSF 61] and [https://blog.ansi.org/2020/10/lead-drinking-water-regulations-nsf-ansi-372/ 372] which are drinking water standards. The 25 psi models are tested and certified by [https://www.intertek.com/ Intertek] to [https://blog.ansi.org/nsf-ansi-50-2020-equipment-chemicals-swimming-pools/ Standard ANSI/NSF 5]0, equipment for swimming pools, spas, hot tubs, and other recreational water facilities. |
=How it works= | =How it works= | ||
− | The Stenner design is based off a peristaltic pump that consist of a 3 roller head assembly that presses agains a Santoprene tube. It can feed from a proprietary design tank or a regular general purpose tank, you just have to make sure it has a breathing line to a well ventilated area. | + | The Stenner design is based off a [https://en.wikipedia.org/wiki/Peristaltic_pump peristaltic pump] that consist of a 3 roller head assembly that presses agains a [https://www.santopseal.com/services/extruded-santoprene-tubing/ Santoprene tube]. It can feed from a proprietary design tank or a regular general purpose tank, you just have to make sure it has a breathing line to a well ventilated area. |
− | The injection point | + | The injection point must be placed on the return line after any other equipment or device. The injection device includes a check valve to prevent backflow. Tubes are available in 1/4 or 3/8 UV black(chlorine) or White(acid). |
=Advantages= | =Advantages= | ||
Line 19: | Line 19: | ||
= Stenner Pump Models= | = Stenner Pump Models= | ||
==Econ VX and FX Series== | ==Econ VX and FX Series== | ||
− | The Econ VX is a variable speed pump | + | The [https://stenner.com/products/pumps/econ-vx-and-fx-series/ Econ VX] is a variable-speed pump with an adjustable potentiometer. Six different models are available, with output ranges of 0.8 to 38.8 gallons per day. Each model in the VX series is differentiated by its output and pressure range. |
− | The Econ FX is identical to the VX except it is a fixed speed pump without an adjustment. The pump runs at full speed when power is applied. The FX outputs are | + | The [https://stenner.com/products/pumps/econ-vx-and-fx-series/ Econ FX] is identical to the VX except it is a fixed-speed pump without an adjustment. The pump runs at full speed when power is applied. The FX outputs are equivalent to the maximum output of the VX pump. Each model in the FX series is differentiated by the output and pressure range. The pumps are also offered in 24VDC for installations where standard voltage is unavailable. |
==Econ T Series== | ==Econ T Series== | ||
− | The Econ T provides a 24-event control capability with an integral timer in a compact pump for light duty applications requiring a dosing schedule. There are 24 independent programmable on and off events within a 7-day period. The minimum is 1 minute up to a maximum of 23 hours and 59 minutes within each programmed event. Each event can be programmed for a specific ON time and | + | The [https://stenner.com/products/pumps/econ-t-series/ Econ T] provides a 24-event control capability with an integral timer in a compact pump for light duty applications requiring a dosing schedule. There are 24 independent programmable on and off events within a 7-day period. The minimum is 1 minute up to a maximum of 23 hours and 59 minutes within each programmed event. Each event can be programmed for a specific ON time and OFF time in increments by hour and minute. The control panel with an LCD display has a programmable clock using a 24-hour format and a battery backup to maintain the internal time and programmed event settings. The display indicators represent the days of the week, operating mode, and the events. During operation, the panel displays the current day, time and mode of operation. |
== Pentair IntellipH== | == Pentair IntellipH== | ||
− | The | + | The [https://www.pentair.com/en-us/products/residential/pool-spa-equipment/pool-automation/intelliph_ph_controller.html Pentair IntellipH] is an add-on to complete [[Pentair Automation Systems|Pentair automation]] like the EasyTouch and IntelliCenter. It includes the Stenner pump, 5-gallon tank, and controller. |
==Hayward== | ==Hayward== | ||
Hayward acid or liquid chlorine feed system offers a high capacity 15GPD pump that can be used with AquaRite Pro, ProLogic, OmniLogic and Commercial CAT controllers. | Hayward acid or liquid chlorine feed system offers a high capacity 15GPD pump that can be used with AquaRite Pro, ProLogic, OmniLogic and Commercial CAT controllers. | ||
− | =Tanks= | + | =Stenner Tanks= |
− | Tank Systems are available for the Classic Series Single Head pumps, the S Series pumps, and the Econ Pump Line. Most Tank Systems consist of the tank and pump shipped pre-assembled to save time on installation. The Tank System for the S Series is shipped with the pump boxed separately within the tank box to protect it during shipping. The S Series pump will easily slide onto the pre-installed mounting bracket on the tank. | + | [https://stenner.com/products/tank-systems/ Stenner Tank Systems] are available for the Classic Series Single Head pumps, the S Series pumps, and the Econ Pump Line. Most Tank Systems consist of the tank and pump shipped pre-assembled to save time on installation. The Tank System for the S Series is shipped with the pump boxed separately within the tank box to protect it during shipping. The S Series pump will easily slide onto the pre-installed mounting bracket on the tank. |
Tank Systems and Tanks are available in UV-resistant gray or translucent white in 3 sizes. | Tank Systems and Tanks are available in UV-resistant gray or translucent white in 3 sizes. | ||
− | + | *7.5-gallon (28.4 liters) | |
− | + | *15-gallon (56.8 liters) | |
− | + | *30-gallon (113.6 liters) | |
The polyethylene construction is both lightweight and rugged. The tank has incremental solution level indicators and is equipped with a child-resistant lid. The pumps are vertically mounted over the tank containment basin. | The polyethylene construction is both lightweight and rugged. The tank has incremental solution level indicators and is equipped with a child-resistant lid. The pumps are vertically mounted over the tank containment basin. | ||
=Maintenance= | =Maintenance= | ||
− | Stenner pumps require very little maintenance, mainly replacing the Santoprene tube. | + | Stenner pumps require very little maintenance, mainly replacing the Santoprene tube. Depending on the inspection, it is suggested that this be done every year. |
=Replacement parts= | =Replacement parts= | ||
Everything is available for replacement or service with easy DIY instructions and even videos <ref> https://www.youtube.com/user/StennerPumpCompany</ref> | Everything is available for replacement or service with easy DIY instructions and even videos <ref> https://www.youtube.com/user/StennerPumpCompany</ref> | ||
+ | |||
+ | =Forum Discussions= | ||
+ | |||
+ | *[https://www.troublefreepool.com/threads/stenner-liquid-chlorine-pump-how-to-choose-and-install.169591/ Stenner liquid chlorine pump - How to choose and install] | ||
+ | *[https://www.troublefreepool.com/threads/stenner-pump-for-chlorine-help-with-sizing-and-install-ideas.160690/ Stenner pump for chlorine. Help with sizing and install ideas] | ||
+ | *[https://www.troublefreepool.com/threads/stenner-install-chlorine-injection.122176/ Stenner Install Chlorine Injection] |
Latest revision as of 12:41, 1 April 2025
Stenner Pumps
Stenner Pumps offer a totally enclosed design with a brushed motor for light duty or general intermittent applications. The pumps work well for fluid transfer of Muriatic acid or Liquid Chlorine. The ease of maintenance and replacement parts make it Ideal for a DIY pool owner.
This systems can be used together with automation or independent. There are many models of stenner pumps but the ideal for pool use are Fixed speed with or without timer activation. This way you only have to determine how much run time for the pump to dose. The pump is approved by cULus for indoor and outdoor use and carries NSF 61 and 372 which are drinking water standards. The 25 psi models are tested and certified by Intertek to Standard ANSI/NSF 50, equipment for swimming pools, spas, hot tubs, and other recreational water facilities.
How it works
The Stenner design is based off a peristaltic pump that consist of a 3 roller head assembly that presses agains a Santoprene tube. It can feed from a proprietary design tank or a regular general purpose tank, you just have to make sure it has a breathing line to a well ventilated area.
The injection point must be placed on the return line after any other equipment or device. The injection device includes a check valve to prevent backflow. Tubes are available in 1/4 or 3/8 UV black(chlorine) or White(acid).
Advantages
- Solution is not in contact with moving parts
- Pump head requires no valves, allows for easy maintenance
- Self-priming against maximum working pressure, foot valve not required
- Pump does not lose prime or vapor lock
- Pumps off-gassing solutions and can run dry
- Output volume is not affected by back pressure
Stenner Pump Models
Econ VX and FX Series
The Econ VX is a variable-speed pump with an adjustable potentiometer. Six different models are available, with output ranges of 0.8 to 38.8 gallons per day. Each model in the VX series is differentiated by its output and pressure range.
The Econ FX is identical to the VX except it is a fixed-speed pump without an adjustment. The pump runs at full speed when power is applied. The FX outputs are equivalent to the maximum output of the VX pump. Each model in the FX series is differentiated by the output and pressure range. The pumps are also offered in 24VDC for installations where standard voltage is unavailable.
Econ T Series
The Econ T provides a 24-event control capability with an integral timer in a compact pump for light duty applications requiring a dosing schedule. There are 24 independent programmable on and off events within a 7-day period. The minimum is 1 minute up to a maximum of 23 hours and 59 minutes within each programmed event. Each event can be programmed for a specific ON time and OFF time in increments by hour and minute. The control panel with an LCD display has a programmable clock using a 24-hour format and a battery backup to maintain the internal time and programmed event settings. The display indicators represent the days of the week, operating mode, and the events. During operation, the panel displays the current day, time and mode of operation.
Pentair IntellipH
The Pentair IntellipH is an add-on to complete Pentair automation like the EasyTouch and IntelliCenter. It includes the Stenner pump, 5-gallon tank, and controller.
Hayward
Hayward acid or liquid chlorine feed system offers a high capacity 15GPD pump that can be used with AquaRite Pro, ProLogic, OmniLogic and Commercial CAT controllers.
Stenner Tanks
Stenner Tank Systems are available for the Classic Series Single Head pumps, the S Series pumps, and the Econ Pump Line. Most Tank Systems consist of the tank and pump shipped pre-assembled to save time on installation. The Tank System for the S Series is shipped with the pump boxed separately within the tank box to protect it during shipping. The S Series pump will easily slide onto the pre-installed mounting bracket on the tank.
Tank Systems and Tanks are available in UV-resistant gray or translucent white in 3 sizes.
- 7.5-gallon (28.4 liters)
- 15-gallon (56.8 liters)
- 30-gallon (113.6 liters)
The polyethylene construction is both lightweight and rugged. The tank has incremental solution level indicators and is equipped with a child-resistant lid. The pumps are vertically mounted over the tank containment basin.
Maintenance
Stenner pumps require very little maintenance, mainly replacing the Santoprene tube. Depending on the inspection, it is suggested that this be done every year.
Replacement parts
Everything is available for replacement or service with easy DIY instructions and even videos [1]