  1. L

    False low salt reading (IC-40) - Flow sensor changed twice.

    Hi Everyone, My predicament: IC-40 only about 3 years old. It is big for my pool, so duty cycle is low. Only runs at 45-50% in summer. Started getting low salt reading. Cell is clean and had very low deposit. Salt is fine by mine and pool store verification. Salt is about 3800. Cell is...
  2. aerospa

    Brand New IC40 Says Low Salt

    Brand new IC40 says Low Salt ... but the Taylor K1766 says salt is at 3400ppm. Good evening. I just plumbed in a Pentair IC40. I brought salt up to 3400ppm in two steps. I've been aerating and acid dosing to bring TA <=80, and then I'll add cyanuric acid to bring CYA up to 60. In the mean time...
  3. wille

    Inaccurate low salt level warning - Is it SGW or Flow switch?

    I am getting a Low Salt Level warnings on my Hayward T-15 SWG. It is producing chlorine. Salt test with Taylor kit and pool store at 3400. My Hayward Goldline Aqua Pod shows a 2500 reading. What can I test to see if it is the flow switch or the SWG? Thank you in advance for your help and thoughts.
  4. P

    Hayward GLX-PCB-MAIN - Low Salt - Low Current

    I have a GLX-PCB-MAIN which is now not putting out the full 6-7 Amp needed to drive the T-15 Cell. I have verified the Cell - it works correctly. The Board will start with 25V range - reporting 3400 PPM then quickly drop to 1900 PPM while reporting 25.5V at 4 Amp. It did start with 6 Amp...