hayward aqua-rite

  1. S

    Hayward AQR100 guide vs TFP for CYA and FC

    Pool installed Fall 2023 so not tons of experience yet, but I’ve read tons of the TFP docs, classes,…and been using the salt testing kit. I’ve been keeping CYA 60-90 and FC 4-6 but in doing some testing and trying to figure out what Hayward AQR100’s 24 hour swg output is (and still haven’t...
  2. C

    Free - Hayward Aqua rite salt cell circuit board

    I've got a Hayward salt cell system. A few weeks ago, the diagnostic lights stopped functioning. I found some information on this website and identify that the circuit board had gone ( most likely the Thermistor ) ((Hayward Aqua Rite - No lights on, but LCD display works; what to do? )) I...
  3. H

    How many gallons in pool?

    Good morning! I'm not a first time owner, but I really didn't know where else to post this. We have lived in our house with pool for about 5 years. They did not leave us ANY information about the pool, so it's kind of been educated guessing from the beginning. I have been trying to understand...
  4. F

    intake seal hayward tcell cholorinator leak

    starting up my pool this year and last I'm having trouble with the intake side of the chlorinator leaking. I have replaced the oring and still can't get a leak free seal. Does anyone have any recommendations or thing they've tried that work consistentantly?
  5. ULY

    Cell on it's last leg?

    Hello pros. First post. Quick run down: Pool is small 9000 gal Heated Salt Hayward T-3 cell Hayward Aquarite panel Age unknown I noticed the water was starting to green a bit. Heavy Texas sun and Tropical Storm Nicholas seems to have diluted the water. Did a quick taste test and no salt...
  6. J

    Hayward Aqua Rite Salt Cel - Need Help

    About a month ago noticed the lights on the Aqua Rite said to check cell. The cell was caked so I did the acid/water clean and put it back. The cell has never worked since (it's only 2-years old fwiw). Instead of troubleshooting, I bought a new cell and installed it. Seems fine for the first...
  7. D

    Hayward Aqua Rite Salt Chorine Generator - LED on but stuck will not change

    The Hayward Aqua Rite LED screen reads 3100 salt, diagnostics button does not change readings when pushed, Desired Output % does not change salt, and Super Chlorinate/Auto/Off does not change LED reading. Basically the LED reading is stuck on 3100 salt and note of the buttons or dials change...
  8. G

    Experiences with SWGs other than Hayward's Aqua Rite

    I've just repaired the main circuit board on my Aqua-Rite SWG for the second time with absolutely no technical help from Hayward. Do any members have experiences with other makers they'd be willing to share? If I switch makers at some point I'd naturally perfer one with a cell which would...