Search results

  1. F

    jxi heater with versaflo input pipe blew off the heater and drenched me

    you are correct I had put my output jandy valve to the middle and it closed itself when it got power and so the pool was closed no water could escape as I had not pulled the hot tub plugs yet the pipe blew off because all there was was primer and no glue on the fittings LOL so much for...
  2. F

    jxi heater with versaflo input pipe blew off the heater and drenched me

    turned on my pool today for first time this year pressure in the cartridge filter went up past 20 and then the water output from the filter blew off the input pipe to the heater and drenched me the company did not cement it on well but it did last for 6 seasons without a problem tried it again...
  3. F

    water inlet pipe blew off my jxi heater with versaflo

    jandy jxi heater with integrated jxi versaflo bypass turned on main pump and had a water explosion the (poorly installed tiny bit of cement ) input hose blew off the heater but it has worked for 5+ year so doubt it was just the joint seems like water cannot get through the heater either through...
  4. F

    looking for a jandy controller expert for a problem jandy cant solve

    replaced the controller wire and the thing works !! they told me not to bother as it cannot be the wire but it seems like it was fs
  5. F

    looking for a jandy controller expert for a problem jandy cant solve

    I have a jandy controller RS 8 with T revision My heater is a jandy LXI which is plugged into slot 1 2 of the 10 pin connector not into the RS 485 4 pin port and worked fine until recently now The heater works fine in manual mode but I can no longer control it when the heater is set to be...
  6. F

    Unable to control a Jandy LXI heater

    oops - I forgot to ask - re connecting more devices there are 2 red connectors - with 4 pins does it make any difference which one I use or are they both the same and where does one buy the actual connector that slides onto the 4 pins
  7. F

    Unable to control a Jandy LXI heater

    1.My Jandy LXI Heater is working fine in manual mode but I cannot control it with my Jandy RS controller. Yesterday I installed a new CPU and bezel control board ( I am planning on a multi speed pump and needed a newer revision of firmware ) and I hoped it would get rid of the problem but still...
  8. F

    Jandy Pool Actuator Problem Zodiac Unable to help

    great idea I did switch the positions on the controller and the problem did NOT go away. This led me to believe that there was something wrong with the actuator or the wire to the actuator. I took apart the actuator and checked the microswitchs and the left one works when the toggle is down...
  9. F

    Jandy Pool Actuator Problem Zodiac Unable to help

    Have a spillover spa pool with jandy aqualink and 2 jandy 2440 actuators one to switch suction from the pool three suctions to spa and the second to divert water from the spa return to the pool returns. The problem is the second one When I am in service mode and put the pool into spa both...