Search results

  1. Jimrahbe

    Spillover spa drained to level of the jets when turning the pool pump off

    End, Make sure you buy OEM 'guts' for the check valve.. Buying cheap will not solve the problem, as all valves are not identical.. Thanks, Jim R.
  2. Jimrahbe

    Vertical Pipe in middle of spa

    Clint, It should unscrew... Don't try to plug the hole that is left, as water comes through the hole to force your spa to overflow into the Pool, when in the Pool mode. Thanks, Jim R.
  3. Jimrahbe

    Spillover spa drained to level of the jets when turning the pool pump off

    End, The check valve on the far left of your pic is most likely bad or dirty.. That check valve is there just to prevent the spa from draining back into the pool. Thanks, Jim R.
  4. Jimrahbe

    Adding spa to pool

    VT, My guess is that it would cost you $50 or $60 grand to add a spa to your pool... Have you ever been in a gunite spa?? If not, you owe it to yourself to try one, before you ever buy one. Thanks, Jim R.
  5. Jimrahbe

    Spa Mode pump

    22, Each pool/spa can be different, so I would suggest you see what 3,000 RPM looks like.. That said, you should adjust the speed to what works for you. As a test, I would ramp the pump up in speed and see of the pump fills with water or not.. Since you say it works in the pool mode, it...
  6. Jimrahbe

    Spa Mode pump

    22, 2300 seems slow for a Spa speed... But as long it is works that is all that matters.. In the Spa mode there is a lot more back pressure, so it may be normal.. Has it always been this way or is this a new problem?? Thanks, Jim R.
  7. Jimrahbe

    Spa Mode pump

    22, How fast it the pump running in the Spa mode??? Do the spa jets feel and look normal? Is there anything near the spa drains that could effect the water flow?? Thanks, Jim R.
  8. Jimrahbe

    Spa Mode pump

    22, In general, the pump runs faster when in the Spa mode and the basket should be full. It could be you have the pump set up to run too slowly in the Spa mode, or you have an air leak on the Spa intake line. I 'assume' that in the Pool mode the basket is full or close to it.. Thanks, Jim R.
  9. Jimrahbe

    I have a leak through my spa return pipes. Are there one way Spa valves that only allow one direction water flow?

    X, Show us several pics of your equipment pad so we can understand the plumbing.. 95% of the time, when a spa drains down with the pump off, it is a bad check valve in the spa line.. All the spa jets are connected so how did you isolate the problem to two jets.. I suspect that is not your...
  10. Jimrahbe

    Easytouch issue with Mastertemp buttons

    Nit, When you use the Fireman's switch, you are supposed to set the heater to full on at 104 degrees, it does not matter if set to spa or pool. Then when the water temp is below your set point, the relay in the EasyTouch closes and the heater is comes on.. You can just short the green and...
  11. Jimrahbe

    Easytouch issue with Mastertemp buttons

    Nit, Is your heater being controlled by an RS-485 com port cable, or is it controlled by a 2-wire cable to the heater Fireman's switch? Thanks, Jim R.
  12. Jimrahbe

    Spa losing about an inch of water per night

    PM, Not sure what to say.. :scratch: You have done all the right stuff and the spa should not be leaking. :( When original, or new, 2 or 3-way valves are installed, it is very important that no glue gets on the sealing surfaces of the valve body... We have seen cases in the past where...
  13. Jimrahbe

    Spa losing about an inch of water per night

    PM, When the spa drains down to the return jets, it is almost always the check valve in the spa fountain line. (The one you replaced 3 times...) :mrgreen: Show us several pics of your equipment pad and maybe someone here can spot something. Thanks, Jim R.
  14. Jimrahbe

    Question on weeping water prior to pebble sheen going in

    S, You can't stop weeping by adding anything to the inside of the pool. To stop any weeping you have to remove the water outside of the pool. In my case we had to install a drain system and a sump pump.. I am not sure if you have enough weeping to be a problem. I had a massive amount of...
  15. Jimrahbe

    Above ground Spa GFCI question

    m, Not sure what you local rules call for, but I'd want the GFCI right next to the spa. My spa actually takes two GFCI breakers, what about yours??? Thanks, Jim R.
  16. Jimrahbe

    Hot tub water evaporation in spa mode

    112, Sounds to me like normal operation... I'm exaggerating , but if 10 people get in the spa, all the water they displace goes over the spillway.. Once that happens there is no automatic way to get that lost water back... You have to either put it in the pool mode, like JJ mentions above, or...
  17. Jimrahbe

    Hot tub water evaporation in spa mode

    112, How long do you run in just the spa mode??? For the water level to drop where you would notice it, I suspect it would have to be many hours... :scratch: If it drops in an hour or so, then I would suspect that your Return valve is leaking, so that a little water is actually going back...
  18. Jimrahbe

    Showering Before and After Using Hot Tub?

    Gebo, It is just the wife and I and we do not shower before or after our dips in the spa... Right or wrong... I don't care... :mrgreen: Thanks, Jim R.
  19. Jimrahbe

    Jacuzzi hot tub hose that goes nowhere

    C, Some jets need air to operate.. They often just leave an open pipe to provide the air input. Your problem is that there is now water in the air line. I would suspect the jet that you wiggled is either bad or plugged. Thanks, Jim R.
  20. Jimrahbe

    recommended brands

    817, An eight person hot tub is more like a small pool and that is why it cost $40K... :mrgreen: Thanks, Jim R.
  21. Jimrahbe

    Tired of SWCG corroding my heater element

    twg, Your SWCG should not be eating your heater, it is normally due to very low pH... Thanks, Jim R.
  22. Jimrahbe

    Is this an issue… moving part on Jacuzzi jet

    Guy, I have not heard the word "Pseudo" for years.. We used to send RF signals called Pseudo (Fake) to our Radar guided missiles so that they were close to the right frequency before they were launched... Not a word used too often. Thanks for the memories... :mrgreen: Jim R.
  23. Jimrahbe

    Airlock on one jet after refill.

    K, I'd use a shop vac and suck a short burst of water out of the jet.. Did you add water to your spa by just dropping a hose in the tub itself, or did you add water to your skimmer area. In my tub, I get similar issues if I don't fill it from the skimmer area. Thanks, Jim R.
  24. Jimrahbe

    Spa losing water to pool when pump off and is not check valve! Air pressure fixes it though. Clueless!

    B, Thanks for the pics.. The whole purpose for the check valve marked "Heater Return" is to prevent the spa from draining down when the pump is off. The fact that you can shut off the manual Jandy valve and "fix' the problem proves that the water has to be passing through the check valve...
  25. Jimrahbe

    Spa losing water to pool when pump off and is not check valve! Air pressure fixes it though. Clueless!

    B, I assume the Spa Return valve and the check valve are in series on the same pipe.. If so, the only thing that can be wrong is the check valve... So.. Something is not right... :scratch: Please show up several pics of your equipment pad. Thanks, Jim R.
  26. Jimrahbe

    Manufactures chlorine non-recommendations

    T-man, I suspect the hot tub uses mineral cartridges of some type that they want you to buy.. Somewhere, the manual has to have information about how to sanitize the water... I was looking at new hot tubs in the Pool Store that I use to get my liquid chlorine, and they all have some type of...
  27. Jimrahbe

    Hot tub code OH

    G, Well, I assume that your spa's controller thinks the water temp is too high.. OH or Over Heat. Your water may not be too hot, but all that matters is what the controller "thinks".. I suspect that one of your temp probes is bad. Let's see what @RDspaguy has to say.. Thanks, Jim R.
  28. Jimrahbe

    I'm looking for DFW area gunite spa owners....

    Please PM me if you are interested in helping with a review of a new Spa robot cleaner. Thanks, Jim R.
  29. Jimrahbe

    Do I Need Anything Else Electrical?

    GeBo, So, this is a used Hot Tub, or demo model? Anyway, they will wire into the subpanel you installed on the wall... Thanks, Jim R.
  30. Jimrahbe

    Do I Need Anything Else Electrical?

    GeBo, Is the pipe coming out the bottom your AC input line?? Jim R.