Search results

  1. P

    Use of actuators for water features

    Hi I just found that error you mentioned thanks (the names are similar) It is INTELLITOUCH I9+3 PERSONALITY KIT 521221 with power center and screen logic
  2. P

    Use of actuators for water features

    Yes the intellitouch with power center and screen logic will cover 5 pumps. Its a i9+ 3 and expandable. Purchased 2 VSPs already- own the whisperflo from old set up (was told to buy one more VSP) 3 HP VSP 4 bubblers and 4 deck jets (will have two 2" bypass) 3 HP VSP 6' waterfall and 2 laminars...
  3. P

    Use of actuators for water features

    @MyAZPool I read you had some insight on this and with the new actuators and automation more may be possible (please read through my initial post ) thanks!! @jblizzle I will not be running all the features/pumps all the time. Only when we are using the pool. I didnt get any guidance and had...
  4. P

    Use of actuators for water features

    No, here is the planned set up: We want to be able to run each set of features independently. Thanks
  5. P

    Use of actuators for water features

    @Jimrahbe @Bama Rambler @mknauss
  6. P

    Use of actuators for water features

    Hello I am trying to plumb 4 bubblers and 4 deck jets on one 3 HP Intelliflo VSP. In order to have the bubblers work independently from the deck jets the plumber says I need TWO Pentair 521485 IntelliValve Valve Actuators (they are listed as setting just the right amount of flow for two water...
  7. P

    Water Feature plumbing help needed PLEASE :)

    Hi I just met with the plumber and he labeled it. What do you think about safety? thanks
  8. P

    Water Feature plumbing help needed PLEASE :)

    Yes we are going to add two 3inch lines to the right of or near the return on the right of the photo. Its for the waterfall. Im most worried about hair getting sucked in or little kids being sucked to it (safety to prevent drowning/injury). Will any cover work for this? are there flat ones as...
  9. P

    Water Feature plumbing help needed PLEASE :)

    Thank you. No there isnt 3 feet below the water line. Therefore, im going to have them turned into returns. Two will be unused (saved for later incase we decide to do solar heat) and two will be bypass/blow off for the deck jets so they can be used alone without the bubblers as they will share a...
  10. P

    Water Feature plumbing help needed PLEASE :)

    the two on the left are suction lines and they are 3 feet apart but the placement on the wall isnt safe they are too high up I think? (multiple 3HP VSP's). If they are, isnt this unsafe? what do you think can be done at this point? Im thinking they need to be changed to a skimmer? I think the...
  11. P

    Water Feature plumbing help needed PLEASE :)

    @mas985 thank you for your reply. Pentair said I can use the 2" line. However, they said I needed more suction and when I mentioned where the suction was it brought up a red flag. I think these are suction lines and they shouldn't be in the wall and so high up and close together. I think this...
  12. P

    Water Feature plumbing help needed PLEASE :)

    Newbie remodeling an old pool and have had a lot of issues. Please Help. 40 X 20 pool (incudes new 8X20 baja)plus a large attached spa In pool: Two 2” suction lines Two 2” return lines Run to 6” waterfall is approx. 90 ft Run to laminars is a little less but not by that much Pumps 1 whisperflo...