  1. B

    Removing heater from equipment pad

    Not much to add but don't often see anyone from Petaluma here. Since it is above the pool level I don't believe you need to shut any valves, looks pretty straight forward.
  2. B

    Choosing a new pool filter.

    On my pentair 420 the whole center assy removes by pulling up, the vertical protrusions center it and provide friction to keep it in place.
  3. B

    Bleed filter thingy...

    I have had the same one for 5 years, why does it matter if it has a few dents, as long as there are not holes.
  4. B

    Anyone else have leaking actuated valves?

    Same here, my solar valve developed a leak last year, still about the same now, slow drip.
  5. B

    Equipment Placement relative to pool

    I was answering this question.
  6. B

    Equipment Placement relative to pool

    My equip is approx 4' lower than the pool, priming is never a problem, works good.
  7. B

    Jacuzzi Sherlock 120 filter oring question

    My friend has a pool with this filter. It is leaking where the two filter halves join. Looking on the internet I bought a new oring the part diagram shows only one. Upon taking his filter apart there are two large orings there, the top one seems to be a little smaller cross section or maybe its...
  8. B

    my brothers sand filter

    I guess there's not a "factory support" for it. We'll figure something out or maybe someone will post something. another question, where would a vacuum be connected?
  9. B

    my brothers sand filter

    The test in the tf-100 didn't even hide the dot at all. I was surprised the cya was 0 but I guess either someone drained and refilled somewhat recently or they have always used liquid cl, I think the first option is more likely. I didn't see a floater anywhere though.
  10. B

    my brothers sand filter

    last pic, this needs some attention, I'm surprised it hasn't failed. The hose from the filter is not supported except by a bungee cord.
  11. B

    my brothers sand filter

    Here are the test results from today: fc 10, cc 2.5, tc 12.5, ph 7.2, ta 150, ch 160, cya 0, temp 52. I am surprised the cya was at 0, I added a little too much chlorine but I think it will be gone pretty quick. He's not living there yet so this was just a temporary to reduce the algae, well go...
  12. B

    my brothers sand filter

    Thanks for the info, I typed a reply a couple hrs ago but forgot to hit the submit button. you are right, when turned to backwash the water came out brown.
  13. B

    my brothers sand filter

    Thank you, I was hoping that it wasn't the 25 bolts.
  14. B

    my brothers sand filter

    My brother is buying a house with a intex pool with I think a sand filter. I'll get a pic today to help figure out what kind. There is one intake from the pool, one hose to waste, and one return back to the pool. There is a valve on the top with various positions, Filter, filter to waste...
  15. B

    vs-3050 Pump running dry.

    I think your right.
  16. B

    vs-3050 Pump running dry.

    I guess it comes on at 35 deg and the only option is "on" or "off", I wanted to set it to come on at 32 deg but unless someone knows how to I guess that's not an option. Thanks for the reply.
  17. B

    vs-3050 Pump running dry.

    So I pulled a dumb move yesterday. I wanted to soak my cartridge elements overnight to clean them. My pump starts at 9:45 am and stops at 4:00pm. Friday night I disassembled everything and pressed the "service" button on the easy touch thinking this would stop any thing from turning on, even...