Search results

  1. R

    Hayward DE filter

    Thx for the insight. Will play with it tomorrow and respond back with results. I don't see any amount of buildup in the grids which is why I suspected it was time to replace them. I've been in the house for 6 years and suspect the pool is at least 12 years old. Not sure of the age of the...
  2. R

    Hayward DE filter

    Yo Frog, soak them in what? I'll kiss them if it'll make the pool cleaner.....
  3. R

    Hayward DE filter

    I've been getting a lot of DE in the pool and whenever I vacuum it up I see clouds of DE from the return. It's been gradually getting worse. Thoughts on whether it's time to replace the grids or if it's something else?
  4. R

    Pump pressure rising, air in filter

    filter is a Hayward DE6000 model, pump is Hayward 2007x10 model.
  5. R

    Pump pressure rising, air in filter

    Ok, last fall before I shut everything down I noticed that the pressure in the filter kept rising and air was in the filter/basket. Backwashing temporarily fixed the problem but the pressure would rise in an hour or so and air would increase in the filter basket. I replaced the motor last year...
  6. R

    impeller removal problem

    Thanks. I took a hacksaw and cut the impeller in half until I hit the drive shaft of the motor. It split almost entirely at that point after prying it at the base. The rest came off by using the hack saw blade alone, without the saw handle. It took about 25 minutes (including the extended...
  7. R

    impeller removal problem

    Ok, I've got this problem too. What's the best way to break-off the old impeller? Went on vacation last week and came home to a dead motor. When I took apart pump, impeller looked like it was on a slight angle but not much. The impeller came off the old motor but I couldn't tighten it on the...
  8. R

    Converting to a two speed motor

    Being a pool newbie, what's the advantage of a two-speed versus a single-speed motor? My motor is working fine, but when it goes (and it will someday) this info will be handy.
  9. R

    Filter/Pump Problem

    Now all I have to do is find the kid with the air soft gun...............
  10. R

    Filter/Pump Problem

    mas985 nailed it. I took the pump apart and there was an obstruction. A pellet from an air soft gun got caught in the motor and it wasn't turning. Thanks to all for the feedback.
  11. R

    Filter/Pump Problem

    Thanks mas985, I'll look into that as well. Looks like I have my work cut out for me tonight, but then again, I love a project.
  12. R

    Filter/Pump Problem

    frustratedpoolmom - Water in the skimmer basket is high and I probably need to let some water out. I was planning on backwashing a few times until the water is clear, so I wasn't worried about the water level. Jason - I'll try again tonight. I made about 10 attempts yesterday. Most of the...
  13. R

    Filter/Pump Problem

    I opened my pool last weekend and ran into a problem yesterday. I had been vacuuming up the crud on the bottom of the pool and lost pressure. I have a Hayward DE filter and I cleaned the filter and tried starting again, still no pressure. The pump turns on and sucks out the water from the...