Search results

  1. J

    Replaced Jandy VSP motor with non-VSP motor and now status says ePump offline and aquapure won't turn on.

    I just figured it out, go to menu, system setup, VSP setup, click on Application column where epump was, and change that to not installed. The offline epump message disappeared from status and now the aquapure is working. If anyone ever does this don't forget that step.
  2. J

    Replaced Jandy VSP motor with non-VSP motor and now status says ePump offline and aquapure won't turn on.

    Replaced Jandy VSP motor with non-VSP motor and now status says ePump offline and aquapure won't turn on. The pump is moving water fine but the aquapure won't turn on because it still thinks there is an ePump installed and that it is offline. I originally took out a non-VSP pump and installed...
  3. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    Sensor fixed it. Not one error since. Thanks everyone for the help I would not have known to get that specific sensor. I was thinking of ditching Jandy too, had already got a VS FLO-PRO though, and I just redid the Jandy water colors lights which was not cheap. Only thing I have not replaced...
  4. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    Well it is not the cell, and not the DC cord. I just replaced both, one at a time. Sensor comes tomorrow (new one with interface in the middle of the wire run) that should fix it I would think! Still can't believe the one I had died it is spotless. Like the salt cell I had.
  5. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    That is what I was looking at, from the pics, looks like the kits are coming with the either the cell I have, or the cell I have plus the exact same little board I just got. I will order cell and dc cord, then sensor separately to make sure I get the right one.
  6. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    Question, I am pricing new kits, and it looks like that sensor with the status board in the middle of the cable only has two silver sensors, the one I have has 3 silver sensors. Why is that?
  7. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I have installed the new IQ20-RS board and have it working on WIFI, very nice. I would recommend it. I actually found it cheaper at poolsupplyworld.com $499. I paid $519 at Sunplay. The poolsupplyworld price will not come up until you add it to the shopping cart, if anyone else is looking to...
  8. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I received Zodiac Jandy Adapter Tri Sensor R0537600 for Aquapure and installed it, when I hold the calibration button, the flow light never lights up. I have plenty of flow. Maybe it is too bright for me to see it, but I don't think this will fix the issue. Now gives 172, 183 and 184 (No 186)...
  9. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    When did that come out? My sensor is one year old, and it is spotless so I don't think it is the sensor, I am thinking salt cell. Also when I put the old sensor in, which never gave an error, the salt ppm was just way off, I get the same 172 error. We will see though. I would rather replace...
  10. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    Sure Ping, I never knew this existed either: R0537600 http://cdn.lesliespool.com/wpdf/r0537600_installation.pdf
  11. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    Ping, I ordered that too, they have one you can add to existing sensor inbetween board and sensor wire.
  12. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I do have the new type of sensor, the slotted one, I just replaced it a year ago. I am betting it is the cell, but wouldn't be surprised if it is the sensor since all signs are pointing that way. I am going to put in the new IQ20-RS I will see what errors I get after putting that in.
  13. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    So the pressure washing did nothing still same error. I think consencus on here is I need a new tri sensor, it looks brand new only a year old, and the cell is spotless. I am still suspecting the cell, I don't see what could go wrong with that massive DC cable. So I have ordered IQ20-RS to...
  14. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    OK thanks Ping. I read something else where someone pressure washed the cell I am going to try that today and cross my fingers. Else I will wait for that guy who I got the current tri sensor from and see what he things to do next. I actually had ordered a whole new 'front' board or whatever...
  15. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    @JamesW - I found this on Ebay, couldn't find it anywhere else: Zodiac Jandy Adapter Tri Sensor R0537600 for Aquapure salt sensor OEM NEW - $20 I will install this (if I didn't order something incompatible again like a dumb dumb) and hopefully that has the jumper instructions on the jumper. I...
  16. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    If anyone is interested about the IAuquaLink, here is what Jandy support told me. Board is not compatible, pool was built 2009 and I thought I read these were compatible 2007 and later. Thank goodness for Amazon Prime membership with no hassel return. I am a little confused by below response...
  17. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    Here is what I am looking at I have 3 boards and that is it.
  18. Circuit Board - Copy.jpg

    Circuit Board - Copy.jpg

  19. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I did these and all passed - First Test- Salinity: Press the R-Temp & the Salinity buttons on the PIB, and the Salinity readout button on the UIB. The UIB display should read between 2.7 to 3.1. If the number is outside this range, replace the PIB. Second Test- Low Temp: Press the R-Temp & the...
  20. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    So I am not messing with that wireless board till I get this system fixed again. I actually just put the old sensor in, which I don't remember getting an error with, it was just erratic with the salt ppm reading. So when I put the old sensor in, I am getting 172/180(Heated sensor element not...
  21. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I think I see the problem, there is an iq900 and iq900rs - rs has the front board and I ordered the 900, I didn't know there was a difference.
  22. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I just got the IQ900RS kit and I thought that was going to give me a new front board, all it has is the little board for the wifi! I don't think this is a mistake because it doesn't say anything in the quick install about installing a new main/front board. I guess I am back to square 1.
  23. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I went ahead and ordered the IQ900-RS, someone had it for $253, but I went with one for $266 since it was qualified for Amazon Prime with free two day shipping. Hopefully this will fix it, if it doesn't I guess I am going with a new sensor again. One other thing is I had not mentioned, was for...
  24. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    I saw the post about the jumper, I should have one per rev number. This pool is about 6 years old and I have had it about 2 years, I have never had a problem with these codes, and when I replaced the old sensor it was discolored so looked like it was the original. If I had an issue with the...
  25. J

    Jandy Tri-Sensor 172 and 186 errors - Does IQ900-RS board replace front board?

    My main question was Does the IQ900-RS board replace the 'Front Board'? (is front board the board that the tri sensor plugs into?) I just replaced this sensor mid July of 2014. I am now getting 172 and 186 errors, and immediately figured it was the board, since I just replaced the sensor. Now...
  26. J

    Jandy Watercolors Pool and Spa Light, how to tell if 12V or 120V

    I finally got the pool light, still waiting on the spa light. Pool light works perfectly, I guess the lights go out over a period of time, because the red on splash mode used to be very dim, now it is a bright red, and it also does a yellow I have not seen before. With the red, the purples and...
  27. J

    Jandy Aqualink RS6 - Wired All Button Remote Issue

    I actually asked Jandy/Zodiac the same thing in April, here is what they said: Vista, TechSupport <[email protected]> Apr 20 to me Good afternoon, The part I recommend you have installed is IQ900-RS or IQ20-RS. This part includes a new Aqualink RS board, a Pool/Spa Combo 8...
  28. J

    Jandy Watercolors Pool and Spa Light, how to tell if 12V or 120V

    So I was able to get both light engines with gaskets for $859.90. That saves me about $900 considering if I had the original pool company come out they would have charged me tax too. Hopefully just the light engines are needed :) The lights housing themselves still looks perfect and clear. Will...
  29. J

    Jandy Watercolors Pool and Spa Light, how to tell if 12V or 120V

    OK I tested it, 0V with lights off, 6V (assuming AC) with lights on giving me 12V peak to peak. THANKS OldPoolGuy!!!!!! I think I can order my lights now. and hot to hot was 12.4V so I think I am good with 12V lights.