Search results

  1. M

    Plaster VS Stonescapes Minipebbles

    New pool this spring and went with plaster blue quartz , been in new type pebble pool and found rough on the feet and skin. In the end plaster is good if chemistry/cleaning is taken care weekly. Opinion though.
  2. M

    Pentair Heater Control - Board connections

    All done today, finished the flex conduit run to heater. Four things controlled by the Pentair Link2O app. Intelliflo Pump, InteillBrite 5G lights (Relay One), Yard Lights ( Relay Two) and Pentair 400 Heater. Heater on command ramps up pump to 2640 rpm and shuts the bypass valve. When heater...
  3. 22F32B8E-D75A-40DF-A206-AE86D7C1A263.jpeg

    22F32B8E-D75A-40DF-A206-AE86D7C1A263.jpeg

  4. M

    IntelliConnect Review

    I’m quite impressed with the Intelliconnect. Pump control, heater control and even intellibrite 5g light control. I’ve added a 24 vac transformer and dpdt relay to move actuator valve when heater is turned on. That was installed in the heater. All equipment is Pentair.
  5. M

    Pentair Heater Control - Board connections

    IntelliConnect, not intellitouch controller. Did some self troubleshooting and the board in this 400 is the same as the Sta-Rite heater, 42002-0007s board. That board external or keypad jumper is labeled jmp1. Wish Pentair would change their labels and manuals when they use something other. Now...
  6. M

    Pentair Heater Control - Board connections

    Attempting to control a remote pool connection to the IntelliConnect. A few items. The pentair 400 heater control board does not have Jmp3 but does have Jmp1. Also, what looks like the pool , common and spa connection for remote on or off, nothing is label with pin outs or letters. Thinking the...
  7. EEFCB6B4-472A-4E11-BAB3-D9D556B81A4C.jpeg

    EEFCB6B4-472A-4E11-BAB3-D9D556B81A4C.jpeg

  8. M

    Pentair Heater Control - Board connections

    Attempting to control a remote pool connection to the IntelliConnect. A few items. The pentair 400 heater control board does not have Jmp3 but does have Jmp1. Also, what looks like the pool , common and spa connection for remote on or off, nothing is label with pin outs or letters. Thinking the...
  9. M

    Pentair Intelliconnect...

    The latest programming update on the Intelliconnect allows a temp probe connection (520272) thus you can control a heater. So with this update, you can have have Pentair Intelliflo (up to 5 RS-485 comm lines), Pentair MasterTemp Heater and one more free relay. If you all got a person of wit, you...
  10. M

    Another Solar Touch Controller Problem

    solar heat command should be on when water temp is below start temp set point which should be 6 degrees delta from water to solar temp if such is the set point as programmed into the utilities menu, correct? from talking to Pentair today, they state the scheduled clean and thus pump running have...
  11. M

    Another Solar Touch Controller Problem

    Just installed SolarTouch with Intelliflo VS pump and for some reason when you think the solar heat should be on, device actually states solar off. I have ext sped 2 set to 2500 rpm for head pressure correction. Speed1 set for schedule run from 10 pm to 4 am. Speed 2-4 set to manual. Comm...
  12. M

    Solar Heater - Draining

    Purchased pool and solar heater with home. Solar heater has an older Pentair controller and valve. There is a check valve on the inlet to the solar heater once the diverter valve ports to heater, no other isolation installed. Seems like heater drains when valve ports to pool since water flows...