    Pentair AmerLite and SpaBrite Lights Not Working

    As far as I can tell, it is a home run from the light to the Easytouch panel. Nothing else in line. I used a gfci tester on the gfci and it tested ok. I guess if its working for the pool lights and tests ok, it must be ok and the spa light must be at fault. Will let it dry out for a few days...
  2. W

    Pentair AmerLite and SpaBrite Lights Not Working

    Removed the load side of the gfci and it does not trip. Removed the spa load and it does not trip. There are three lights (circuits) connected through the gfci; 2 x pool lights and 1 x spa light. The pool lights work fine with no tripping of the gfci. The spa light trips the gfci every time...
  3. W

    Pentair AmerLite and SpaBrite Lights Not Working

    Tried a few more things and determined that the GFCI was tripping on the spa light. Guess this is the 120V circuit to both spa and pool lights. The spa light was dry when I checked the bulb. What else could be tripping the circuit?
  4. W

    Pentair AmerLite and SpaBrite Lights Not Working

    I rarely use my lights, but had friends over and was showing them the pool. After about a minute from turning them on, all lights (spa and pool) went out. The pool lights (2) and the spa light (1) are on separate relays. I pulled each light and checked the bulbs for continuity with a...
  5. W

    Mastertemp bypass valve

    BTW, the valve was broken (tips where it clips to the retainer ring to hold the spring were broken). The valve made it through 3 x 90o bends and into the SWG. Water flow pushed the valve into the flow switch in the SWG and broke that too. Had to replace the flow switch and the valve kit...
  6. W

    Mastertemp bypass valve

    Other insert piece replaced [attachment=2:1yozo48v]IMG00126-20120421-0929.jpg[/attachment:1yozo48v] First gasket is put in place, then manifold cover plate [attachment=1:1yozo48v]IMG00127-20120421-0931.jpg[/attachment:1yozo48v] Everything back in order, working great...
  7. IMG00103-20120421-0753.jpg

    IMG00103-20120421-0753.jpg

  8. IMG00127-20120421-0931.jpg

    IMG00127-20120421-0931.jpg

  9. IMG00126-20120421-0929.jpg

    IMG00126-20120421-0929.jpg

  10. W

    Mastertemp bypass valve

    Broken valve (bottom) and new valve assembly (top) [attachment=2:3hwu600z]IMG00120-20120421-0839.jpg[/attachment:3hwu600z] New valve assembly in place [attachment=1:3hwu600z]IMG00121-20120421-0921.jpg[/attachment:3hwu600z] The manifold insert is in 3 pieces (like a puzzle), easier to...
  11. IMG00122-20120421-0923.jpg

    IMG00122-20120421-0923.jpg

  12. IMG00121-20120421-0921.jpg

    IMG00121-20120421-0921.jpg

  13. IMG00120-20120421-0839.jpg

    IMG00120-20120421-0839.jpg

  14. W

    Mastertemp bypass valve

    The manifold insert (plastic) needs to be removed [attachment=2:336cmcx6]IMG00115-20120421-0832.jpg[/attachment:336cmcx6] The bypass valve assembly without the valve (its broken) [attachment=1:336cmcx6]IMG00118-20120421-0833.jpg[/attachment:336cmcx6] Had to remove the broken valve plate with...
  15. IMG00119-20120421-0836.jpg

    IMG00119-20120421-0836.jpg

  16. IMG00118-20120421-0833.jpg

    IMG00118-20120421-0833.jpg

  17. IMG00115-20120421-0832.jpg

    IMG00115-20120421-0832.jpg

  18. W

    Mastertemp bypass valve

    Now we can get to the manifold [attachment=2:mcsuanfs]IMG00111-20120421-0809.jpg[/attachment:mcsuanfs] Remove the thermostat first [attachment=1:mcsuanfs]IMG00128-20120421-0942.jpg[/attachment:mcsuanfs] Now the manifold [attachment=0:mcsuanfs]IMG00113-20120421-0823.jpg[/attachment:mcsuanfs]
  19. IMG00113-20120421-0823.jpg

    IMG00113-20120421-0823.jpg

  20. IMG00128-20120421-0942.jpg

    IMG00128-20120421-0942.jpg

  21. IMG00111-20120421-0809.jpg

    IMG00111-20120421-0809.jpg

  22. W

    Mastertemp bypass valve

    For anyone interested, here's how it goes: Heater in line before SWG [attachment=2:67v8lfwg]IMG00104-20120421-0754.jpg[/attachment:67v8lfwg] Remove sides and top [attachment=1:67v8lfwg]IMG00108-20120421-0803.jpg[/attachment:67v8lfwg] Got to remove the manifold side by removing bolts to heater...
  23. IMG00109-20120421-0803.jpg

    IMG00109-20120421-0803.jpg

  24. IMG00108-20120421-0803.jpg

    IMG00108-20120421-0803.jpg

  25. IMG00104-20120421-0754.jpg

    IMG00104-20120421-0754.jpg

  26. W

    Mastertemp bypass valve

    What are the implications if it isn't repaired? Can I just put the valve back in place?
  27. W

    Mastertemp bypass valve

    Anyone have a clue how to replace/repair the manifold bypass valve in a Pentair Mastertemp heater? I'm not even sure this is a repairable item. It appears that the bypass valve popped loose and made its way to my chlorinator (which subsequently broke the flow switch and stopped my chlorinator...
  28. DSC_0116 (640x425).jpg

    DSC_0116 (640x425).jpg

  29. DSC_0115 (640x425).jpg

    DSC_0115 (640x425).jpg

  30. W

    Algae line on flagstone at water surface

    Thanks for the suggestions and I plan to investigate further with fc loss test, shocking, etc. Its interesting that the suggestions are related to the condition of the water. This algae is not in the water (note that there is no algae growing below the water surface). I'm curious, will the...