Search results

  1. J

    Losing prime

    Re: Losing prime Check my post I just made. Might help you find any air leaks. Suction Side air leak issue; Possible fix for priming issues It should find any air leaks on your plumbing as long as it is between your skimmer and the outlet of the pump, (and not underground :D) The water...
  2. J

    Suction Side air leak issue; Possible fix for priming issues

    Re: Suction Side air leak issue In this particular instance, the O-ring on one of my PVC unions had come out of place slightly. However for good measure, I also removed all the pvc threaded connections and sealed them with pipe joint compound (link below). Something I recently discovered while...
  3. J

    Suction Side air leak issue; Possible fix for priming issues

    I only visit here occasionally each year so this may have been posted before. I have been troubleshooting a small air leak on the suction side of my pump for over a year. It causes occasional issues with pump priming, and I almost always have small air bubbles in my return vents. Since finding...
  4. J

    Why so much dislike for Flocculent?

    That makes sense. Most of the people that come to here looking for help are very inexperienced in general with all the chemicals and what the purpose of the different products actually do, so adding extra things like flocculents and clarifiers to the mix doesn't really help in this since. I...
  5. J

    Why so much dislike for Flocculent?

    Long time lurker, rare poster. I was doing some reading through various old posts her and it seems like there is a general dislike for things like flocculent and clarifier. Why is everyone so against it? Does it do something bad to the pool? Is it more of a money/time thing? I ask, because I...
  6. J

    CYA sock help

    I just tied the sock with a small rope running to the handle on a used bleach bottle half filled with water. Set the bleach bottle above one of the skimmers and let the sock hang. The return jet pushes the sock away from the side of the pool so its not resting on anything. Give it some squeezing...
  7. J

    Pool water slightly cloudy

    Pool is finally clear! Thanks for all the help everyone! Took a week of doing a SLAM. Here's a couple pics of how clear the pool is. 1 during the day and 1 at night with the lights on. This is looking down into 8 feet of water.
  8. J

    SLAM and TA

    That seems to be what the problem was. Thanks! I tested again today wiping between drops and the TA came out to be 100 again.
  9. J

    SLAM and TA

    I did not wipe the tip of the bottle. I read that in the instructions but didn't really understand why I would need to do that. I will retest tomorrow :) Previously I was using the K-2006 test outside next to the pool when I got the TA of 100 and the TF-100 inside on my kitchen counter when i...
  10. J

    SLAM and TA

    What would cause the TA to almost double when I have done nothing else except add bleach for a week?
  11. J

    SLAM and TA

    Thanks everyone for your help getting me through a SLAM process, it seems that everything is clearing up nicely. I do have one questions. Before I started my SLAM, my PH was 7.4 and my TA was 100. I know that when FC is really high that PH measurements are not accurate. Is this the same for...
  12. J

    Pool water slightly cloudy

    Ok, I got my TF100 kit in! After testing twice today already, I definitely have not been putting in enough chlorine over the last few days to keep up with a slam. I put 121oz of 8.25% bleach in this morning. When my TF 100 got here via USPS, I tested around 1pm, and it was at 11 FC. I put in...
  13. J

    Pool water slightly cloudy

    I was looking back through my pics of the pool being filled up. I think I definitely have way more algae then I thought. Just need the TF-100 to arrive so I can start the SLAM again.
  14. J

    Pool water slightly cloudy

    I only added 1/4 cup DE as suggested by Piolin and it seems to be doing a better job without overloading the filter. My TF-100 is tentatively supposed to be here tomorrow, so I can start testing the water again, and start/finish the SLAM. It seems to be getting there, I can actually see the...
  15. J

    Pool water slightly cloudy

    It seems this may be what is happening, the 1/2 cup I put in earlier barely moved the needle at all. After about an hour it had gone up to 15psi from 10. Now, after 4 hours its up to 23 psi. Water is still moving good so I haven't stopped the pump yet.
  16. J

    Pool water slightly cloudy

    Since my Test kit ran out, I don't know what levels i'm at. I have a new TF-100 on the way. But, knowing that 121oz of 8.25% bleach is enough to raise FC by a little over 4 in my 18000 gallons. I have been dumping in a gallon each evening, and 1 more gallon spread out throughout the day after...
  17. J

    Pool water slightly cloudy

    I ran out of my FAS-DPD testing reagents. None of the local pool places carry it. Is there a way to monitor high chlorine levels with one of the basic kits you get at a store until I get my replacement? The ones I've seen only go to 5 TC.
  18. J

    Pool water slightly cloudy

    I am in the process of doing a SLAM right now. I will be keeping the FC in the 15-16 range based on the CYA chart with my CYA at 40.
  19. J

    Pool water slightly cloudy

    I tested again this morning at 8:30am FC: 15.5 CC: 0 pH: 7.7 Overnight it dropped from 16 to 15.5 I figured I would include a picture to help show you what it looks like. Its overcast right now so its hard to get a picture without reflections. You can see the cloudiness on the sides where the...
  20. J

    Pool water slightly cloudy

    Ok, I tested the water 2 hours after the chlorine addition. The PH jumped alot. I think I remember reading that high FC levels mess with pH measurements. I'm going to assume my CYA is somewhere in the 30-40 range since that is what I tested earlier today and there was no water...
  21. J

    Pool water slightly cloudy

    I have been dissolving CYA in a sock for 3 days. I put 4 lbs in total with the last of it dissolved this morning. I did a CYA test at 5pm and it read between 30 and 40 ppm when the circle disappeared. The FC showed 6.4 at the same time, PH was 7.4. The last time i added chlorine was last night...
  22. J

    Pool water slightly cloudy

    Thanks! I will pick up some more chlorine and get to work and see what happens.
  23. J

    Pool water slightly cloudy

    Hello all, I have been on the board for a couple years now, but haven't really asked many questions since my pool has been under construction for about a year and a half. We finally got the pool finished Monday of this week. 18000 Gallon Pool with 1HP pump a Hayward Sand filter. I think its a...
  24. J

    Vinyl Liner Pool remodel. Leaking and Pool deck.

    Thanks Suz. Can anyone answer my question about the pool structure or if they see any issue with my plan?
  25. J

    Vinyl Liner Pool remodel. Leaking and Pool deck.

    Hello everyone, I started reading hits forum last year when we moved into our new house that had a pool. This was my first pool and I have learned tons from this site. I used TFPC to take care of our pool last summer and it worked great. Having said that, our liner has a leak in the deep end...