Search results

  1. A

    FC loss, but CC is zero

    I have not been diligent at measuring chlorine - I had some cloudiness start when the season went from cool to warm - I thought I caught it. I had never measured CC in the past, but I got an upgraded FAS DPD kit with CC measure - seeing it at zero had me looking for "other problems" instead of...
  2. A

    FC loss, but CC is zero

    Thanks for the reply. I always think I have things dialed in for the year, than bam, something changes.
  3. A

    FC loss, but CC is zero

    My season started off great (of course pool water was cool) - as things heated up I started to see a little cloudiness. I have 9 year old gunite/plaster pool. All chemicals balanced when opened in may - CYA 50, PH 7.6 - I don't have TA or CH handy but they were all good. I just replaced my...
  4. A

    Leaky pump, can’t tell where.

    Thanks, i just have this fear that I will order a seal kit, then find diffuser has a problem, order a diffuser, then find impeller is cracked...... But I just priced pumps, seals are way cheaper. And thanks for the hint on better seals, that is new to me.
  5. A

    Leaky pump, can’t tell where.

    I have a 1.5 hp Hayward super 2 pump. It started leaking last season and I can’t tell from where. I assume it is the shaft seal as it it is 9-10 years old. Should I bother replacing the seals, or just replace the entire unit? This pump runs my Paramount cleaning system. I am concerned if I only...
  6. A

    Slightly cloudy, can't seem to find why

    I have an in floor/wall pool cleaner, so mixing can't be it. And the heads clean stairs so shouldn't be that. Pool was drained for a month while tile was replaced and shocked with new water. Oh well
  7. A

    Slightly cloudy, can't seem to find why

    I did the overnight test, and i dropped from 9.5 to 7 PPM to i guess something is living in there. I will have to SLAM it - wish i knew how it happens when it never went below 7ppm this year so far.
  8. A

    Slightly cloudy, can't seem to find why

    I will have to add it to my signature - good point - cloudiness has been consistent for a week - i had also dumped in a gallon of chlorine a week ago to raise the PPM a bit, but no effect on water quality. It hasn't got better or worse. Gunite/plaster pool. SWG, Hayward cartridge filter (4 -...
  9. A

    Slightly cloudy, can't seem to find why

    I started the season late, drain and fill due to new tile that I installed. Everything looks great, but the water is just slightly cloudy - i can see the main drain fine, but it just isn't crystal clear. My fill water is always high alkalinity so i spend every year working to get TA down, and...
  10. A

    Cantilever Decking Best Practices - Decking to tile to pebble-plastic between?

    I guess i am surprised that the coping which is adhered to the bond beam via thinset/mortar would expand/contract and not pop off, and the same could occur for the tile, but yet the joint between them would move enough to crack when they are both adhered to the beam with the same mortar/thinset...
  11. A

    Cantilever Decking Best Practices - Decking to tile to pebble-plastic between?

    Thanks for the feedback.. i worked for a pool company in my younger days, but we always poured cantilever and used the plastic cove edge. I was in Virginia and there was snow. In Ohio now with similar seasons. Even if the grout line cracks due to some coping movement, i can't see that taking...
  12. A

    Cantilever Decking Best Practices - Decking to tile to pebble-plastic between?

    I am re-tiling my pool (3rd time this has had to be done as first time the frostproof tile failed at being frost proof, and second time installer installed wrong) and so do it right, i am doing it myself. Gunite pool, plaster finish, old tile removed and surface is clean and flat (chipping and...
  13. A

    Alway adding acid - all numbers are great otherwise - ideas?

    Thanks everyone... will do some aeration to get back down to around 50 TA and see how it goes.
  14. A

    Alway adding acid - all numbers are great otherwise - ideas?

    I would have to check fill water, but have not had to add any with rain this year. No water features - I do have in floor cleaning system, but it doesn't aerate. I would like to see my pool stay at 7.4 to 7.6 for some period of time. it seems like it was more stable after the aeration for...
  15. A

    Alway adding acid - all numbers are great otherwise - ideas?

    Thanks, I had my TA at 60 PPM and it seemed to demand acid still - so i thought maybe it was too low. From the Taylor kit, i thought that to low or to high would cause bounce, so I raised it from 60 to about 90 - still the same bounce. Sounds like i need to read up on borates. My pool is...
  16. A

    Alway adding acid - all numbers are great otherwise - ideas?

    So, I drained and acid washed this year to remove scale, so I paid extra attention this year. Aerated for about a week, to get the TA down, then added a little bit of Bicarb to raise it. Currently TA is about 90-100, but PH rises every 2 days - I am guessing it is from my SWG. CA, CH...
  17. A

    calcium scale and acid wash (empty pool)

    Thanks, it sounds like I could make my mixture stronger... yeah, I don't really want to buy stronger acid - and if I recall, to get the stronger stuff you had to buy a carboy. I guess I will try 75% acid to water, and I could always try a small spot at full strength. Thanks for the feedback.
  18. A

    calcium scale and acid wash (empty pool)

    I had a problem with calcium scale last year, but also had a problem with the glazing on my tile chipping so i decided to do an acid wash this year. I have a 20K gunite/plaster pool that is 4 years old. I have a feeling the scaling was due to my high pH as the CH seemed to be fine - but no...
  19. A

    spanning skimmer throat?

    Thanks - yes , I was hoping maybe someone had done a coping project. I am now looking at putting in thicker coping and covering my deck with some kind of tile.... Would love advice if anyone has it. I just noticed, I have a signature that I never set... funny, never lived in Arkansas nor do i...
  20. A

    spanning skimmer throat?

    Hi everyone, What is the recommended method for spanning the skimmer throat when using 4" wide coping? I used to build pools, but we used deck-o-form or the old cast coping pieces that were larger. I have seen references to a stainless steel skimmer bar - but I have never seen such a thing...
  21. A

    Low FC - can't figure out why

    Thank you everyone! FC was about 36 at bed time and 35 this am. Cleaning the light niche was the key. SWG was off. Quick question. How does leaving the SWG off during SLAM save cell other then not running for a few days? Is there something about high CL and electricity that doesn't mix? At...
  22. A

    Low FC - can't figure out why

    Now just wait for more titrant to arrive. Should be today. I am out of the reagent, but can't quit now. Although, I think tonight will finally be it.
  23. A

    Low FC - can't figure out why

    Woohoo! Significant progress after cleaning out the light niche. At 9pm I was at 26 and added a bottle of CL - my napkin math estimates 6ppm per bottle. This am I was sitting at 30 ppm. Chlorinator was 100% overnight, but I am getting closer. Previously my overnight drops were huge - with or...
  24. A

    Low FC - can't figure out why

    Yeah, I am going to leave mine out for now. Maybe even leave it out when I winterize.
  25. A

    Low FC - can't figure out why

    The pool opened and cleaned up easily so I thought I was home free. But I didn't slam and the temps were cool. It was the hot weather that really set this off.. BTW - pulled the light and the niche was full of organics. Time to get more chlorine!
  26. A

    Low FC - can't figure out why

    I do have a light niche. What am I looking for? Some kind of solid material growing in there?
  27. A

    Low FC - can't figure out why

    I buy into it. It makes 100% sense. I just had no idea it could take so long. And with all the added salt, I wonder if I will just be draining a large amount of water anyway. I know that based on my FC drop that my SWG will never keep up so liquid CL is my only option for now. And based on...
  28. A

    Low FC - can't figure out why

    Ok. Problem now is I am out of reagent. I guess I will just add 2 gals morning and night until I get more reagent. So it could take days more? I will probably have to drain water to get salt level down.
  29. A

    Low FC - can't figure out why

    I have been adding chlorine for days. My garage looks like a bottle wasteland. Yesterday morning I brought the cl level up to 34 using the 10ml 0.5 FAS DPD concentration. I had been doing it with 5ml sample so each drop was 1ppm as I only have so much titrant. It rained yesterday and my salt...
  30. A

    Low FC - can't figure out why

    Thanks for the advice... I have one gallon left - that is good for about 6ppm in my quick math - Guess i better go get some more.