Search results

  1. xtrsports

    SWG AMPs Start High but Drop

    T-Cell 15 - The AMPs on my Goldline SWG start out at 5.2 and then, somewhere between 90-120 minutes of operation, it drops down to about .82. I say about because the number varies but it's always below 1.0. Is this normal behavior? Is it related more to the T-Cell or the controller? The T-Cell...
  2. xtrsports

    How to Test SWG

    I'm at the start of season 3 for my T-Cell 15 and it doesn't "seem" to be generating chlorine. I switched to tabs and bleach to get the right levels in place. Removed the tabs and FC began a slow decline from 8 to 0. Background: I've got my salt levels at 3200ppm which is between 2700-3400...
  3. xtrsports

    Crack in PVC Light Conduit

    A couple of years ago my PVC conduit running to the deep end light must have frozen and cracked creating a slow leak. I "fixed" it by putting a small layer of epoxy around the area where the wires came out of of the cove. This was fine until last year when I needed to replace the light fixture...
  4. xtrsports

    Light Housing Leak - multiple questions

    Folks, i've read through a number of posts on this subject and am certain this topic is covered but can't seem to pull out the relevant details for my use case... apologies if available elsewhere, please feel free to send a link to an existing thread if easier. Opened pool this year after a...
  5. xtrsports

    Salt Connection with Metals

    Noticed that when I introduce salt into the pool that I get the green tint which, short of draining and refilling, is easily solved with sequestrant (Jack's purple stuff). Reaction happens about 30 minutes after introducing bag(s) of salt. I'm curious as to why this happens? I'm using regular...
  6. xtrsports

    3 T-Cell-15's in 3 years

    This is getting kind of expensive, I've replaced my t-cell 15 each year for the last three years (OEM not generic brand) and can't seem to keep the pool chlorinated. 35k gallon pool, chemical levels fine using a taylor R-2006 kit (but no salt level test), running the generator for a minimum of...
  7. xtrsports

    Can Sequestrant Lower FC?

    Hey... before getting to my question, just wanted to say thanks, I post very infrequently because the experts contributing to this site answers nearly all my questions. Background. I've got well water with high metals and a small leak in the pool. There is an automatic pool leveler that adds...
  8. xtrsports

    All Lights on - SWG Not producing Chlorine

    I'm working with a Goldline controller hooked up to a Jandy Auqarite RS system. I set the goldline generator to be remotely controlled by the Aquarite by emulating the Aquapure generator - (AL-5 setting). All lights are on, power, flow, generating... all green. When I put it in shock mode...
  9. xtrsports

    Trying to get an Aqualink to speak with the AquaRite

    Hey... also having the same problem here... trying to get an Aqualink to speak with the AquaRite... had no problems on using the two until I upgraded the power control board to Firmware R. Using the same wiring configuration, I'm not able to get the aqualink to recognize the Chlorine generator...