  1. M

    Pump not priming and shutting off

    Thanks...haven't checked them in awhile. Will check them tomorrow. Thanks again!
  2. M

    Pump not priming and shutting off

    It is a pentair whisperflo WS-4 pump. The impellor does not appear to be clogged. The impellor does spin...I have not been able find any air leaks. Skimmer is not stuck.
  3. M

    Pump not priming and shutting off

    Hi, It has been awhile, but looking for some guidance. Have a pcc2000 system. The skimmer/in floor system has a hayward ws-4 and 1.5hp sq1152 motor. The pump will not prime...I have replaced both the capacitors (start & run), I cannot find any blockages, clogs or air leaks. The motor shaft is...
  4. M

    V Green 270 screen/interface

    Thanks...I will give it a try...do you know does it save the programming or will I need to re program??
  5. M

    V Green 270 screen/interface

    Hi...installed a V Green 270 pump about 5 months ago based on interactions here on Trouble Free Pool and it was an excellent choice. My problem is...I went out a couple days ago to make an adjustment and found that the screen/interface is blank. It is lit up, but nothing is on the screen. There...
  6. M

    Vgreen 270 variable motor

    Aaaah...thanks cowboy...appreciate it...going nuts trying to figure that out
  7. M

    New Variable Motor

    Thanks James!...really did not want to pull it apart again....so what rpm and time do you think I should run it, based on the info I provided???
  8. M

    New Variable Motor

    My BAD...you are correct Whisperflo
  9. M

    New Variable Motor

    So I have an intellifo WFE-6 pump...inyo told me that the vgreen 270 would be the right size motor...never said anything about the changing out the impeller...should I have done so...and I apologize but some of this thread is above me...apologize for my ignorance... Thanks again for help/guidance!
  10. M

    Vgreen 270 variable motor

    Is there a way to shut off schedule 2 & 3 on a vgreen 270 variable motor?? Thanks
  11. M

    New Variable Motor

    Any idea how to prime/start it the 1st time
  12. M

    New Variable Motor

    Thanks...MUCH APPRECIATED!
  13. M

    New Variable Motor

    I just swapped out an intelliflo motor with a vgreen 2.7 motor. Would like to know the best rpm and amount of time to set it to run at: Location: Phoenix suburb 15-18000 gal pebbletec 2 pumps Filter - new vgreen 2.7 In floor clean/waterfall: 1 hp intelliflo Pentair Clean & Pure Cartridge 420 Had...
  14. M

    Upgrade to VS pump/s

    Thanks ajw22... -Any other alternative VS pumps? I have seen a brand...Harris i think? -Also, any recommendations on HP for the filter pump? Jimrahbe comments on running a 3 HP at 1200 rpm...i was thinking like 1.5, 1.65hp, but DO NOT want to undersize it -Also any recommendations on the IFCS...
  15. M

    Upgrade to VS pump/s

    The timer is not reflective...usually run anywhere from 6-8 hours and costs a large fortune...
  16. M

    Upgrade to VS pump/s

    Thanks for the responses. Motors have been swapped out over the years...so right now the filter pump has a data plate with no HP listed. The IFCS has a 1.5 HP. Previous owner left blueprints that shows IFCS was to have 1HP, but they don't show a specific HP for the filter. Not sure of the timer...
  17. 20210203_113430.jpg

    20210203_113430.jpg

  18. 20210203_113606.jpg

    20210203_113606.jpg

  19. 20210203_113109.jpg

    20210203_113109.jpg

  20. 20210202_153930.jpg

    20210202_153930.jpg

  21. 20210202_153922.jpg

    20210202_153922.jpg

  22. M

    Upgrade to VS pump/s

    Has been years since i last posted... - Paddock built in 2000. - 15000 gal in ground - Paramount PCC 2000 in-floor cleaning - (considered 12 zone i believe) - Pentair Clean & Pure cartridge filter (CCP420) - 2 OLD pumps - 1 pump for filter - 1 pump for in floor/water fall feature Trying to...
  23. M

    Paramount PCC 2000 Valves

    There are 7 joints. 1 center & 6 around it.
  24. M

    Paramount PCC 2000 Valves

    Just replaced a PCC 2000 valve base...dry fit everything and it appeared to fit perfectly. Used purple primer & oatey blue cement. Now it is leaking!! Is there anything do help seal it at this point? Anyway to remove it other than cutting it off? Any help greatly appreciated!!! Thanks, MJ
  25. M

    Debris in line

    I have a PCC 2000. When replacing a valve base some of the PVC piping fell into the valve lines. Anyway to get this out before I start everything back up??